Sealey TA202 User Manual

Ta202, Digital automotive analyser 14 function with ic, Instructions for

Advertising
background image

. . . . . . . . . . . . . . . . . . . . . Continuity

BAT . . . . . . . . . . . . . . . . . Low Battery

. . . . . . . . . . . . . . . . . . . . . Diode

DATA HOLD . . . . . . . . . . . Data Hold

Auto . . . . . . . . . . . . . . . . . Auto Ranging

AC . . . . . . . . . . . . . . . . . . Alternating Current

DC . . . . . . . . . . . . . . . . . . Direct Current or Voltage

1.1.

PERSONAL PRECAUTIONS

When using this meter, please observe all normal safety rules concerning:

Protection against the dangers of electric current .

Protection of the meter against misuse .

Full compliance with safety standards can only be guaranteed if used with the test leads supplied . If necessary, they must be replaced with genuine Sealey

leads with the same electronic ratings . Failure to do so will invalidate the warranty .

DO NOT use leads if damaged or if the wire is bared in any way .

1.2.

GENERAL SAFETY INSTRUCTIONS

Familiarise yourself with the applications, limitations and hazards of the meter .

IF IN ANY DOUBT CONSULT A QUALIFIED ELECTRICIAN.

When the meter is linked to a measurement circuit, do not touch unused meter terminals .

When the scale of the value to be measured is unknowen set the selector to the highest range available .

Before rotating the range selector to change functions, disconnect test leads from the circuit under test .

WARNING! Never perform resistance measurements on live circuits.

Always be careful when working with voltages above 60Vdc or 30Vac rms . Keep your fingers behind the probe guards while measuring .

When not in use, store the meter carefully in a safe, dry, childproof location . Storage temperature range -10

°C to 50°C .

Never apply voltage or current to the meter that exceeds the specified maximum .

The user shall ensure that test probes are correctly selected in order to prevent danger . Probes shall be selected to ensure that adequate barriers guard against

inadvertent hand contact with live conductors under test and that probes have minimal exposed probe tips . Where there is a risk of the probe tip short circuiting

with other live conductors under test, it is recommended that the exposed tip length shall not exceed 4mm .

Layout: (Refer to fig . 1 .)

1 . Large LCD display

2 . Rotary switch

3 . COM, negative input jack

4 . Positive (+) input for AC/DC Voltage, Current, Hz, %duty, Cycle, Ohms, Diode, Continuity,

Capacitance, Temperature (°C or °F), RPM, Dwell and Pulse Width .

5 . Positive (+) input jack for AC/DC µA/mA .

6 . Positive (+) 20A input jack for 20A AC/DC measurements .

7 . Data Hold and backlight push button .

8 . Relative push button .

9 . RPM, DWELL, Hz%, CYL, mS ± button .

10 . Mode push button .

INSTRUCTIONS FOR:

DIGITAL AUTOMOTIVE ANALYSER 14 FUNCTION

WITH IC

MODEL No:

TA202

1. SAFETY

Input Limits

Function

Maximum Input

V AC or V DC

700V AC, 1000V DC

mA AC/DC

400mA AC/DC

A AC/DC

20A AC/DC (30 secs

max every 15 minutes)

Frequency

Resistance

Duty Cycle

Diode Test

Continuity

Temperature

RPM

DWELL

Pulse Width

250V AC/DC

Extra large, hi-contrast LCD display with 36mm high digital read-out and backlight . Durable bi-composite case and integral stand suitable for the toughest

workshop conditions . Features millisecond pulse-width function for accurate measurement of fuel injection systems . Includes auto-ranging, data hold and

auto-power off . Supplied with tough nylon carry case and shoulder strap, inductive coupler, for fast reading of engine rpm, test probes and thermocouple .

Symbols & Description

Fig. 1.

Inductive Pickup

Test Probes

Termocouple

TA202 Issue No: 3(L) - 17/06/14

Original Language Version

© Jack Sealey Limited

2. FEATURES

IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE

PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR

PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these

instructions, and properly maintained, give you years of trouble free performance.