InstructIons for:

CALIBRATION RIG FOR MS070

MoDEL no:

MS070CR

thank you for purchasing a sealey product. Manufactured to a high standard this product will, if used according to these instructions

and properly maintained, give you years of trouble free performance.

1. SAFETY INSTRUCTIONS

IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.

USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE

DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

1.1

GENERAL SAFETY

WARNING! Ensure Health & Safety, local authority, and general

workshop practice regulations are adhered to when using this

equipment.

Maintain the

calibration rig in good condition.

replace or repair damaged parts. Use genuine parts only.

Non-authorised parts may be dangerous and will invalidate

the warranty.

Locate the

calibration rig in a suitable working area, keep

area clean and tidy and free from unrelated materials.

Keep the

calibration rig clean to ensure accurate

performance.

DO NOT use outside in damp or wet weather conditions.

DO NOT allow untrained persons to operate the calibration rig.

DO NOT leave the calibration rig unattended.

WARNING! the warnings, cautions and instructions

contained within this document cannot cover all possible

conditions and situations that may occur. It must be

understood that common sense and caution are factors

which cannot be built into this product, but must be

applied by the operator.

Original Language Version

Ms070cr Issue: 2 - 20/07/12

1.2 LASER SAFETY

the Ms070 utilises a class 2M laser that emits low

levels of visible radiation light (i.e. wavelengths between

630 and 640 nanometres) which are safe for the skin but

not inherently safe for the eyes. the class 2M emission limit is set

at the maximum level for which eye protection is normally afforded

by natural aversion responses to bright light. Accidental eye

exposure is therefore normally safe, although the natural aversion

response can be overridden by deliberately staring into the beam,

and can also be influenced by the use of alcohol or drugs.

WARNING! Do not look or stare into the laser beam as

permanent eye damage could result.

DO NOT direct the laser beam at any person’s (or animal’s)

eyes as eye damage could result. If the beam is obstructed by

a person during use, release the contact switch immediately.

DO NOT use the equipment while under the influence of

alcohol, drugs or whilst on medication.

Be aware that reflections of the laser beam from mirrors or

other shiny surfaces can be as hazardous as direct eye

exposure.

2. INTRODUCTION

used to check and adjust the alignment of the lasers on Model no.

Ms070 Motorcycle Wheel Alignment tool. this unit will allow

workshops to check and adjust in-house.

© Jack sealey Limited

3. SET-UP

3.1

Rig set up: the twin laser units as seen in fig.1 need to be

clamped either side of the calibration rig as shown in fig.2.

3.1.1 Position the left hand laser unit with the rod attached on the

left hand side of the rig and insert the rod through the hole in

the rig. slide the right hand laser unit onto the rod and up to

the other side of the rig, followed by the spring and clamp

unit.

3.1.2 Ensure that the shouldered fixing on the side of the left hand

laser from which the rod emerges passes into the hole in the

side of the rig so that both laser units lay completely flush

either side of the calibration rig.

fig.1

fig.2

Advertising