2. INTRODUCTION & SPECIFICATIONS

3. OPERATING INSTRUCTIONS

4. MAINTENANCE

WARNING! Ensure you read, understand and apply safety instructions.

IMPORTANT . As a guide limit the maximum continuous running time for the pump to six hours, followed by three hours downtime.

3.1. fit appropriate discharge pipe to pump outlet and secure with clip. Ensure the diameter of the discharge pipe is same as, or greater

than, the outlet diameter. A smaller pipe will adversely effect the pump flow rate.

3.2.

Position pump in the water, and place the outlet pipe securely in the discharge receptacle or area. We recommend the pump is

submerged with its discharge outlet facing up to release any trapped air.

3.3.

Plug the pump into the electrical mains supply and switch on. The pump will automatically turn on as the level of water rises (fig.3A).

As water level lowers, the float will automatically switch the pump off as it reaches the minimum height (fig.3B). The float may be

adjusted by shortening or lengthening the cable using the notch in the handle. The pump will switch on if the water level is up to or

above the maximum length of the float cable. To function correctly the float must move freely. Ensure the float can do so and

that the cable is not restricted. check that the pump and discharge are working correctly.

3.4.

The water into which the pump is placed will act as the motor cooling agent. for this reason the pump must remain submerged at all

times. Should the pump have to be used in shallow water

DO NOT operate for more than 10 minutes. failure to follow this rule will

damage the unit and will invalidate your warranty.

NOTE: See fig.4 to determine minimum clearance required if using the pump in a restricted area, such as a well or a trough.

WARNING! With the exceptions listed below in "TROUBLESHOOTING", all pump, float, electrical cable service/maintenance and

repair must only be undertaken by an authorised service agent. Failure to observe this rule may be dangerous and will invalidate

your warranty.

WARNING! Ensure the pump is disconnected from the mains power supply before attempting any service or maintenance.

4.1.

Keep all parts of the pump clean. rinse, drain and allow to dry before storing pump.

4.2.

regularly check the water inlet on the base of the pump to ensure there are no blockages. To access the impeller, carefully undo the

base screws and remove base. clean impeller and replace base ensuring that the “o” ring is correctly located.

DO NOT dismantle any other part of the unit.

fig.3

fig.4

Manufactured from corrosion resistant materials with stainless steel body and motor case. Massive maximum head of 40mtr makes this unit

ideal for wells. fitted with automatic cut-out. Minimum water depth of 32mm. Designed for clean water although these pumps will accept small

particles up to 0.5mm. Suitable for the effective drainage of cellars, sinks, cisterns, baths and the general transfer of water.

a. Motor operates but

there is no suction.

b. reduced water

volume for level

of water
c. The pump will not

start or suddenly

stops during

operation.

1. no electrical power.

2. float not working

3. Impeller is jammed.

1. check cable, plug and fuse.

2. contact authorised service agent.

3. clean the pump.

1. Discharge pipe bent, or pinched.

2. Discharge pipe too narrow.

3. Pump partially blocked.

1. Straighten pipe

2. use wider diameter pipe.

3. clean pump.

1. Water level below minimum suction depth.

2. Air bubbles in pump accumulated during submersion,

or float is incorrectly positioned so pump does not stop

at minimum level and sucks in air.

3. clogged intake filter or discharge pipe

1. Stop the pump.

2. release air by inclining the pump and

re-immersing it in water.

3. remove dirt, and clean the unit.

TROUBLESHOOTING

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: no liability is accepted for incorrect use of this product.

WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.

INFORMATION: for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK Distributor, Sealey Group,

Kempson Way, Suffolk Business Park

,

Bury St. Edmunds, Suffolk,

IP32 7Ar

www.sealey.co.uk

Web

email

Original Language Version

WPS92A Issue: 1 - 14/11/13

© Jack Sealey Limited

500 500

600

1" BSP

female

port

float

switch

Moulded 3 pin plug

with 10mtr flying lead

Moulded

carry/hoist

handle

Model no:................................ WPS92A

cutout:.....................................Automatic

outlet:......................................1" BSP female

Maximum output:.................... 92ltr (20gal)/minute

Minimum Water Depth:............32mm

Maximum Water Depth:...........7mtr.

Maximum Particle Size:...........0.5mm

Maximum Head:......................40mtr.

Motor Power:...........................1000W

Supply:.................................... 230V

fig.2

Environmental Protection.

recycle unwanted materials instead of disposing of them as

waste. All tools, accessories and packaging should be sorted,

taken to a recycle centre and disposed of in a manner which

is compatible with the environment.

WEEE Regulations.

Dispose of this product at the end of its working life in compliance

with the Eu Directive on Waste Electrical and Electronic Equipment.

When the product is no longer required, it must be disposed of in an

environmentally protective way. contact your local solid waste

authority for recycling information.

Advertising