S1C63558 TECHNICAL MANUAL

EPSON

11

CHAPTER 2: POWER SUPPLY AND INITIAL RESET

2.2.4 Terminal settings at initial resetting

The output port (R) terminals and I/O port (P) terminals are shared with special output terminals and
input/output terminals of the serial interface. These functions are selected by the software. At initial
reset, these terminals are set to the general purpose output port terminals and I/O port terminals. Set
them according to the system in the initial routine. In addition, take care of the initial status of output
terminals when designing a system.
Table 2.2.4.1 shows the list of the shared terminal settings.

Table 2.2.4.1(a) List of shared terminal settings (Rxx)

Terminal

name

R00
R01
R02
R03
R10
R11
R12
R13

R20–R23

Special output

Terminal status

at initial reset

R00 (HIGH output)
R01 (HIGH output)
R02 (HIGH output)
R03 (HIGH output)
R10 (HIGH output)
R11 (HIGH output)
R12 (HIGH output)
R13 (HIGH output)
R20–R23 (HIGH output)

FOUT

FOUT

XRMUTE

XRMUTE

XTMUTE

XTMUTE

TOUT

TOUT

BZ

BZ

XBZ

XBZ

HFO

HFO

HDO

HDO

Table 2.2.4.1(b) List of shared terminal settings (Pxx)

Terminal

name

P00–P03

P10
P11
P12
P13
P20
P21
P22
P23
P30
P31
P32
P33

Special output

Serial I/F

*2

Terminal status

at initial reset

P00–P03 (Input & Pull-up *1)
P10 (Input & Pull-up *1)
P11 (Input & Pull-up *1)
P12 (Input & Pull-up *1)
P13 (Input & Pull-up *1)
P20 (Input & Pull-up *1)
P21 (Input & Pull-up *1)
P22 (Input & Pull-up *1)
P23 (Input & Pull-up *1)
P30 (Input & Pull-up *1)
P31 (Input & Pull-up *1)
P32 (Input & Pull-up *1)
P33 (Input & Pull-up *1)

CL

CL

Clk-sync. Master

SIN(I)

SOUT(O)

SCLK(O)

SIN(I)

SOUT(O)

SCLK(O)

Clk-sync. Slave

SIN(I)

SOUT(O)

SCLK(I)

SRDY(O)

SIN(I)

SOUT(O)

SCLK(I)

SRDY(O)

FR

FR

Async.

SIN(I)

SOUT(O)

SIN(I)

SOUT(O)

∗1

When "with pull-up" is selected by mask option (high impedance when "gate direct" is selected)

∗2

The P10–P13 I/O terminals are used for serial I/F (1) and the P30–P33 I/O terminals are for serial I/F (2).

For setting procedure of the functions, see explanations for each of the peripheral circuits.

2.3 Test Terminal (TEST)

This is the terminal used for the factory inspection of the IC. During normal operation, connect the TEST
terminal to V