Preparation / Installation

Prior to installation

Important: Ensure that a qualified electrician, or
a person trained to carry out electrical installations,
performs the electrical installation.

Familiarise yourself with all the instructions and

diagrams in this manual, as well as with the light
itself, before you install it.

Before installation ensure that the circuit, to which

the light will be connected, is not energised. To
do this, remove the fuse or switch off the circuit
breaker in the fuse box 0 position.

Use the voltage tester to verify the de-energised

status.

Installation

3433-025L and 3435-024L:

Unscrew the light body

2

from the connection

housing

1

by loosening the screws

3

coun-

ter-clockwise (Fig. A).

3434-024L:

Unscrew the cover

11

from the connection

housing

1

by loosening the screws

12

coun-

ter-clockwise (Fig A).

Unscrew the lamp shade

10

from the connec-

tion housing

1

by loosening the screws

13

counter-clockwise.

3433-025L, 3434-024L and 3435-024L:

Use the holes in the connection housing

1

,

which are intended for the screws, to mark the
drill holes.

Now drill the fixing holes (ø approx. 6 mm, depth

approx. 40 mm). Be careful not to damage the
supply line.

Now insert the rawlplugs

4

into the drill holes.

Open the membrane for the mains connection

lead

6

with a thorn or a sharp knife.

Insert the mains connection lead

6

through the

membrane.

Fasten the connection housing

1

with the screws

included in delivery

5

.

Pull the protective tube

8

over the mains con-

nection lead

6

.

Connect the connection cable of the light to

the power cord

6

using the terminal block

7

(Fig. C).

Also ensure that the colour connection of the

wires is correct when connecting (L or 2 = black
or brown, N or 1 = blue).

Now connect the earth wire (3 = green-yellow)

to the marked earth terminal (see Fig. C).

3435-024L:

Use a clean, lint-free cloth to insert the lamp.
Carefully insert the lamp

14

E14, 5.5 W, into

the socket and tighten clockwise (Fig. B).

3433-025L and 3435-024L:

Screw the light body

2

to the connection

housing

1

again by tightening the screws

3

clockwise (Fig. D). Ensure the rubber seals

9

are positioned correctly.

3434-024L:

Screw the lamp shade

10

to the connection

housing

1

by tightening the screws

13

clock-

wise.

Ensure the rubber seals

9

are positioned

correctly.

Screw the cover

11

to the lamp shade

10

by

tightening the screws

12

clockwise (Fig. D).

3433-025L, 3434-024L and 3435-024L:

Check for correct fitting.
Your light is now ready for use (Fig. E).
Reinsert the fuse or switch the circuit breaker

back on.

3436-025L:

Unscrew the light body

2

from the connection

housing

1

by loosening the screws

3

coun-

ter-clockwise (Fig. A).

Use the holes in the connection housing

1

, which

are intended for the screws, to mark the drill holes.
Ensure that that you fasten the connection hous-
ing

1

with the arrow facing upwards (on the

rear of the connection housing).

Now drill the fixing holes (ø approx. 6 mm,

depth approx. 40 mm). Be careful not to dam-
age the supply line.

Now insert the rawlplugs

4

into the drill holes.