Specifications – Emerson Islatrol RM-120-10R User Manual

Page 2

Advertising
background image

Emerson Network Power.com

Emerson Network Power.

The global leader in enabling

Business-Critical Continuity

.

AC Power

Connectivity

DC Power

Embedded Computing

Embedded Power

Monitoring

Outside Plant

Power Switching & Controls

Precision Cooling

Racks & Integrated Cabinets

Services

Surge Protection

Headquarters

Surge Protection

328 Water Street

Binghamton, NY 13901

T: 607-724-2484

T: 800-288-6169

F: 607-722-8713

1805 N.E. 19th Avenue

Ocala, FL 34470

T: 352-732-3029

T: 800-648-4076

F: 352-867-1237

10020 E. Knox Avenue

Suite 50

Spokane Valley, WA 99206

T: 509-777-2300

T: 800-953-3701

F: 509-927-0435

Technical Support

800 288 6169 Toll-Free

607 724 2484 Phone

607 722 8713 Fax

While every precaution has been taken to ensure accuracy and

completeness in this literature, Emerson Network Power

assumes no responsibility, and disclaims all liability for dam-

ages resulting from use of this information or for any errors

or omissions.

© 2007 Emerson Network Power. All rights reserved

throughout the world. Specifications subject to change

without notice.

All names referred to are trademarks or registered trademarks

of their respective owners.

SL-22095 (R05/07) Printed in USA

Business-Critical Continuity

, Emerson Network

Power and the Emerson Network Power logo are

trademarks and service marks of Emerson

Electric Co. ©2007 Emerson Electric Co.

Specifications

Islatrol

®

RM Series 120 VAC Rackmount

Rated Voltage

120V

Rated Current

15A & 20A

Peak Surge Current

20kA/mode, 40kA/phase

Response Time

<5ns

EMI/RFI Filtering

60dB Max

LED Indicators

Green – Power On

Green – Ground OK

Green – Surge Circuit OK

Digital Meter (Optional)

Voltage, Amps, Watts, VA, Hz, PF, Kwh, and Clock

Input Power

15A Models SJT 14/3C Power Cord (15ft) with NEMA 5-15P Plug

20A Models SJT 12/3C Power Cord (15ft) with NEMA 5-20P Plug

NEMA L5-20P Plug - Optional

Output Receptacles

15A Models Front – (2) NEMA 5-15R

Back – (10) NEMA 5-15R

20A Models Front – (2) NEMA 5-20R

Back – (10) NEMA 5-20R

Thermal Protection

Thermal Protected MOVs

Overcurrent Protection

Circuit

Dimensions

1.75”H x 19”W x 2.0”D (1U)

Safety Agency

UL 1449 Recognized

Warranty

1 year

Edco RM-CAT6-16R Channel Rackmount

DC Breakover Voltage

8.2 Volts

Insertion Loss

<.1dB

Connectors

RJ-45 Type

Transmission Speed

10baseT, 100baseT, 1000baseT

Peak Surge Current

10kA @ 8x20µs

Response Time

<1ns

Dimension

1.75”H x 19”W x 6.25”D (1U)

Warranty

1 year