Operation, Using the temperature display, Using the alarm function – Silvercrest Z30170 User Manual

Page 7

Advertising
background image

9

GB

Operation

Note: In the weighing mode settings for
water and milk, the device displays the vol-
ume (ml / floz) of the liquid in the bowl. This
function is intended to replace the use of a
measuring jug for liquids. Please note that
in particular the volume of milk depends on
the fat content, the origin of the milk and
other factors. The volume displayed there-
fore corresponds to an average value.



You can press the Digital timer / UNIT /
Alarm / - button

4

to switch between the

displayed units

13

,

14

. The following units

can be used in the measurements:
Weight: Gram (default setting), oz, lb
Water: ml (default setting), floz
Milk: ml (default setting), floz
Note: The measurement unit oz (ounce) is
still in common use for foods and is the
equivalent of approx. 28.35 g. The meas-
urement unit lb (libra = Latin for pound) is
the equivalent of approx. 453.59 g and
equals 16 oz. The measurement unit floz
(fluid ounce) is the equivalent of approx.
28.4 ml. 100 ml is therefore the equivalent
of approx. 3.5 floz.

Weighing out foods:
Note: When you are weighing heavy items,
place them slowly and carefully on to the
weighing bowl

1

to avoid damaging the kitch-

en scale.

1. Place an ingredient into the weighing bowl

1

. The weight is immediately shown in the

display.

2. Press the TARE button

2

to zero reset the

display. The display shows “0” and the tare
indicator

20

will light up.

3. Now add the desired quantity of the second

ingredient. You can read the added quantity
directly in the display.

4. Repeat steps 2 and 3 until all the required

ingredients have been added.



5 kg

Note that the maximum load on

the scale is 5 kg.

Note: If the scale is overloaded, then the
display shows “

”.

Note: If no button is pressed within a period
of two minutes, the kitchen scale’s display
automatically shows the time.



Using the temperature
display



Press the MODE / + button

5

until the

device enters the temperature mode. This
comes after the weighing mode.



Temperature measurement is carried out at
an interval of approximately 10 seconds.



You can press the Digital timer / UNIT /
Alarm / - button

4

to switch the indicator

12

between °C and °F.

Note: If no button is pressed within a period
of two minutes, the kitchen scale’s display
automatically shows the time.



Using the alarm function



Press the MODE / + button

5

until the

device enters the alarm mode. This comes
after the temperature display.



Press the SET / WEIGHT MODE button

3

to enter the settings mode. The minute value
flashes.



You can use the MODE / + button

5

or the

Digital timer / UNIT / Alarm / - button

4

to

set the value.



Press the SET / WEIGHT MODE button

3

to store the set value and move on to setting
the hours. The hour value flashes.



You can use the MODE / + button

5

or the

Digital timer / UNIT / Alarm / - button

4

to

set the value.



Press the SET / WEIGHT MODE button

3

to store the set value and leave the settings
mode.

Note:

If no key is pressed within 10 seconds,

the set value will stop flashing and the alarm
time is set to the value shown in the display.

63925_silv_Digitale_Küchenwaage_content_LB4.indd 9

21.02.11 17:45

Advertising