A

UTOMATIC

S

AFETY

F

EATURES

:

Your pellet Stove has the following safety features:
A. The stove will shut off when the fire goes out and the exhaust temperature drops below 120°F

(49°C).

B. The stove has a high temperature safety switch. If the temperature on the hopper reaches 200°F

(93°C), the auger will automatically stop and the stove will shut down when the exhaust temperature

cools. If this happens, call your local dealer to reset the 200°F (93°C) high limit switch. ALSO FIND

THE REASONS WHY THE UNIT OVERHEATED.

C. The unit has a convection fan control over-ride. This function causes the convection fan to reach its full

speed when the temperature at the back of the firebox reaches 160°F (71°C). This is a normal safety

feature of your unit. To compensate for the fan cycling action that may occur, turn up the blower

control proportionately to the heat output.

D. If the power goes out, the unit will stop running. When the power comes back on, the stove will not

restart unless the exhaust temperature is still above 120°F (49 °C).

S

LIDER

/D

AMPER

S

ETTING

:

This is used to regulate the airflow through the pellet stove.
Circuit Board Model: A Qualified Service Technician or Installer should set the Slider Damper.
SPECIAL NOTES:

����� ���� ���

������ �����

�� ���������

����� ��

��������

���� ����

������

�������� ���

Figure 2: Slider /

damper positions.

Pellet quality is a major factor in how the Pellet stove will operate. If the pellets have

a high moisture content or ash content the fire will be less efficient and has a higher

possibility of the fire building up and creating clinkers (hard ash build-up).
If the fire should happen to go out and the Dial-A-Fire has been set on the lowest

setting, the Slider Damper should be pushed in slightly, decreasing the air in the

firebox or the Dial-A-Fire and Auger Trim can be turned up slightly.
If, after long periods of burning, the fire builds up and overflows the burn pot or

there is a build up of clinkers, this would be a sign that the pellet quality is poor,

this requires more primary air, the slider damper must be pulled out to compensate.

Pulling the slider damper out gives the fire more air.

6

The easiest way to make sure that an efficient

flame is achieved is to understand the

characteristics of the fire.

• A tall, lazy flame with dark orange tips,

requires more air – Open slider (pull out)

slightly.

• A short, brisk flame, like a blowtorch, has too

much air – Close slider (push in) slightly.

• If the flame is in the middle of these two

characteristics with a bright yellow/orange,

active flame with no black tips then the air is

set for proper operation.

Figure 1: Efficient Flame.