Accessory kits, Trouble shooting, Compressor does not run – Elektra Beckum Mega 500 D User Manual

Page 8: Air tool is not supplied with sufficient pressure, Repairs, Environmetal protection, English

Advertising
background image

15

ENGLISH

diameter 8 mm.
Stock-no. 090 105 4550

Accessory kits
L

Accessory Kit LPZ 7-S
comprising: Blow gun, tyre inflator
gauge, tyre valve nozzle, needle tip
nozzle, paint spray gun, spray gun,
self-storing coil air hose.
Stock-no. 090 100 3858

• Accessory Kit LPZ 7-P

(not illustrated)
comprising: Blow gun, tyre inflator
gauge, tyre valve nozzle, needle tip
nozzle, paint spray gun, spray gun,
10 m braided air hose.
Stock-no. 090 100 3890

• Accessory Kit LPZ 6 (not illustrated)

comprising: Blow gun, tyre inflator
gauge, tyre valve nozzle, needle tip
nozzle, paint spray gun, 5 m braided
air hose.
Stock-no. 090 104 4487

• Accessory Kit LPZ 4 (not illustrated)

comprising: Blow gun, tyre inflator
gauge, paint spray gun, self-storing
coil air hose.
Stock-no. 090 101 3845

• Accessory Kit LPZ 2 (not illustrated)

contains change handle with blow
gun, tyre inflator gauge, paint spray
gun, self-storing coil air hose.
Stock-no. 090 105 5971

A

Danger!
Prior to all servicing:

Switch Off.
Unplug.
Wait until the compressor has

come to a complete stop.

Ensure the compressor and all air

tools and accessories connected
to it are relieved from pressure.

After all servicing:

Check to see that all safety

devices are operational.

Make sure that no tools or other

parts remain on or in the
machine.

Compressor does not run:

• No mains voltage.

− Check cables, plug, outlet and

mains fuse.

• Mains voltage too low.

− Use only extension cables with

sufficient lead cross section (see
"Technical Specifications"). Avoid
using extension cable with cold
machine.

• Compressor was stopped by

unplugging.
− Switch compressor OFF at the

On/Off switch, then ON again.

• Motor has overheated, caused by

insufficient cooling (cooling fins cov-
ered).
− Remove cause for overheating

and allow to cool down for
approx. 10 minutes, then start
again.

Compressor runs but does not build
up sufficient pressure.

• Drain cock on cup of filter/regulator

unit open.
− Close drain cock.

• Check valve leaky.

− Have check valve serviced by

qualified service centre.

Air tool is not supplied with sufficient
pressure.

• Pressure regulator not opened wide

enough.
− Open pressure regulator more.

• Hose connection between compres-

sor and air tool leaky.
− Check air hoses, replace defec-

tive parts if necessary.

A

Danger!
Repairs to electric tools must

be carried out by qualified electrici-
ans only!

Electric tools in need of repair can be
send to the service centre in your coun-
try. See spare parts list for address.

Please attach a description of the fault to
the electric tool.

The machine's packaging can be 100 %
recycled.

Worn out machines and accessories
contain considerable amounts of valua-
ble raw and plastic materials, which can
be recycled.

These instructions are printed on chlo-
rine-free bleached paper.

7.

Trouble Shooting

8.

Repairs

9.

Environmetal protection