Control pass-through, Installation, cont’d – Extron electronic Dual Link DVI Transmitter and Receiver DVI DL 201 Tx User Manual

Page 30

Advertising
background image

DVI DL 201 Tx/Rx • Installation

Installation, cont’d

2-18

Control pass-through

The DVI DL 201 Tx/Rx cannot be

controlled by RS-232 or IR controls.

However, they are able to pass signals

from a control device to a remote device

that is controlled by those signals.

N

The RS-232 and IR

communications are via a

passive pass-through only;

the transmitter and receiver

neither generate nor respond

to these signals.

Use the three-pole, 3.5 mm captive

screw connector on the transmitter

to input RS-232 or IR signals from a

control device. Use the corresponding

connector on the receiver to pass signals

to the output display.

C

The ideal length of exposed wire in the stripping

process is 3/16" (5 mm). If longer than 3/16", the

exposed wires may touch, causing a short circuit.

If shorter than 3/16", the wires can be easily pulled

out even if tightly fastened.

Do not tin the wires. Tinned wire does not hold its

shape and comes loose over time.

3-Pole

Captive Screw

Connector

3/16" (5 mm)

MAX

Tx Rx