Power input, Installation, cont’d – Extron electronic Dual Link DVI Transmitter and Receiver DVI DL 201 Tx User Manual

Page 32

Advertising
background image

DVI DL 201 Tx/Rx • Installation

Installation, cont’d

2-20

Power input

1

.

Connect the captive screw connector from the supplied

12 VDC power supply into the power receptacle.

Twisted pair cable 2, pin 5 carries a 12 VDC power signal.

This remote powering feature allows a single power

supply, connected to the transmitter, to power both the

transmitter and receiver.

C

Power supply voltage polarity is critical. Incorrect

voltage polarity can damage the power supply, the

transmitter, and/or the receiver. Identify the ground

( ) lead by the ridges on the side of the cord (see the

figure below).

12V

0.4A MAX

POWER

Power Receptacle

DC Power Cord
Captive Screw Connector

AC Power Cord

Ground
+12 VDC

External

Power Supply

(12 VDC, 1 A )

Connecting power to DVI DL 201 Tx/Rx

C

The ideal length of exposed wire in the stripping
process is 3/16" (5 mm). If longer than 3/16", the
exposed wires may touch, causing a short circuit.
If shorter than 3/16", the wires can be easily pulled
out even if tightly fastened.

Do not tin the wires. Tinned wire does not hold its
shape and comes loose over time.

2

.

Connect the AC power cord of the power supply unit to a

110 or 220 VAC electrical source.

3

.

When the transmitter or receiver is getting power, either

directly from the power supply or indirectly through the

remote powering feature (receiver), the front panel LED

lights amber.

Power Supply

Output Cord

SECTION A–A

Ridges

Smooth

A

A

Advertising
This manual is related to the following products: