Configuration and Operation

Configuration

Using the EDID Minder to read and store EDID

from a display

During boot up, the DVI-D source device uses Display Data

Channel (DDC) to obtain Extended Display Identification Data

(EDID) from the display device. This allows the output signal to

match the resolution and refresh rate of the display device.
The DVI DL 201 Tx/Rx uses Extron's EDID Minder, which

allows the user to store and use EDID from any display device.

To use this feature, follow these steps:
1

.

Disconnect all devices and cables from the transmitter and

receiver.

2

.

Connect the desired display to the transmitter's Local

Monitor output. For best results, the cable for this

connection should be 15' (4.5 m) or shorter.

3

.

Apply power to the transmitter and the display device. If

necessary, connect the power supply to the transmitter.

4

.

Set the EDID Minder switch on the transmitter

to the on (up) position (see the figure at right).

5

.

Set the Default EDID switch to the off (down)

position (see the figure at right).

6

.

Set the Remote DDC to the off (down)

position to allow DDC routing to go to the

local monitor (see the figure at right).

N

The EDID Minder extracts information only from the

local monitor, not from the remote display.

7

.

Press and release the EDID Minder Store

button. The LED next to the switch turns

from green to amber. This indicates that

the transmitter is reading and extracting

the EDID from the display connected to

the local monitor output.

When the information has been successfully extracted and

stored in non-volatile memory, the LED returns to green.

8

.

Turn off the display and disconnect it from the transmitter.

9

.

Connect the transmitter to the receiver with the three

twisted pair cables.

Transmitter port 1 connects to receiver port 1.

Transmitter port 2 connects to receiver port 2.

Transmitter port 3 connects to receiver port 3.

ON

1 2 3

ON

OFF

DEF

AUL

T EDID

EDID MINDER

REMOTE DDC

STORE

EDID

3-2

Advertising
This manual is related to the following products: