Using the edid minder with the default edid – Extron electronic Dual Link DVI Transmitter and Receiver DVI DL 201 Tx User Manual

Page 35

Advertising
background image

DVI DL 201 Tx/Rx • Configuration and Operation

10

. Power up the transmitter and the receiver. A single power

supply can provide power to both units through the

remote power connection.

11

. Connect the remote display to the receiver output. A local

monitor display can also be connected to the transmitter

output at this time.

12

. Connect the DVI source to the transmitter input.

13

. Check that the transmitter switches are in the positions

described in steps 4-6.

14

. Power on the DVI source device. The source device reads

and uses the EDID information stored in the transmitter

memory and boots up with that resolution.

15

. Power on the remote (and local) display device(s).

N

All display devices must be capable of handling

resolutions equal to or greater than that of the device

used to set the EDID.

Using the EDID Minder with the default EDID

1

.

Set the EDID Minder switch to the on (up)

position and the Default EDID switch to the

on (up) position (see the figure at right). The

position of the Remote DDC switch is not

relevant.

2

.

Connect the source device to the transmitter

input.

3

.

Connect the display device to the receiver

output and, if required, the local monitor to the transmitter

output.

4

.

Connect the transmitter to the receiver with the three

twisted pair cables.

Transmitter port 1 connects to receiver port 1.

Transmitter port 2 connects to receiver port 2.

Transmitter port 3 connects to receiver port 3.

5

.

Power on all devices.

6

.

The source boots using EDID showing a native resolution

of 2560x1600, regardless of the display device.

N

All display devices must be capable of handling

resolutions equal to or greater than the default values.

ON

1 2 3

ON

OFF

DEF

AUL

T EDID

EDID MINDER

REMOTE DDC

3-3

Advertising
This manual is related to the following products: