Configuration and operation, cont’d – Extron electronic Dual Link DVI Transmitter and Receiver DVI DL 201 Tx User Manual

Page 36

Advertising
background image

DVI DL 201 Tx/Rx • Configuration and Operation

Configuration and Operation, cont’d

3-4

Using pass-through mode with DDC routed to a

local monitor

1

.

Set the EDID Minder switch to the off (down)

position and the Default EDID switch to the

off (down) position (see the figure at right).

The position of the Remote DDC switch is not

relevant.

2

.

Connect the source device to the transmitter

input.

3

.

Connect the display device to the receiver

output and, if required, the local monitor to the transmitter

output.

4

.

Connect the transmitter to the receiver with the three

twisted pair cables.

Transmitter port 1 connects to receiver port 1.

Transmitter port 2 connects to receiver port 2.

Transmitter port 3 connects to receiver port 3.

5

.

Power on the local monitor.

6

.

Boot up the source device. The source boots with the

resolution and refresh rate of the local monitor.

N

Because the local monitor is the source of EDID, it must

be powered on before the source device is booted.

7

.

Power on the display device.

N

The remote display device must be capable of handling

a resolution equal to or greater than that of the local

monitor.

ON

1 2 3

ON

OFF

DEF

AUL

T EDID

EDID MINDER

REMOTE DDC

Advertising