Operation, Verifying the operation – Electrolux E30DF74EPS User Manual

Page 24

Advertising
background image

24

Operation

WARNING

WARNING

WARNING

WARNING

WARNING

The range and shut-off valve must be disconnected from the gas supply piping
during any pressure testing exceeding 1/2 psi (3.5kPa).

The range must be isolated from the gas supply piping by closing the shut-off
valve during any pressure testing at or below 1/2 psi (3.5 kPa).

NO

NO

NO

NO

NOTES

TES

TES

TES

TES

If either the oven or cooktop does not operate properly, follow these troubleshooting
steps:

Verify that power and gas are supplied to the range.

Check the electrical connections and gas supply to ensure that the installation
has been completed correctly.

If the appliance still does not work, contact an authorized service company. Do
not attempt to repair the appliance yourself. Electrolux is not responsible for
service required to correct a faulty installation.

VERIFYING THE OPERATION

Before beginning the test procedure, ensure that all cooktop control valves are in
the “OFF” position, and all burner rings, burner caps, and grates are properly
positioned on the top frame. Turn on the gas supply at the shut-off valve.

Turn on the power supply to the range. Select a temperature of 350°F by rotating
the temperature control knob to “350” and selecting “BAKE” with the oven selector
knob. Rotate each knob to the “Off” position to stop the heating process. For model
E48DF76EPS, repeat this test procedure with the companion oven. Test each top
burner separately by pressing and turning one control knob at a time
counterclockwise to the “HIGH” position. All ignitors will spark continuously, but only
the burner with gas flowing to it will ignite. (It will take approximately 4 seconds for
ignition to occur, at which time the ignitors will stop sparking. If ignition does not
occur within 4 seconds, turn off the knob, wait for at least 2 minutes to allow any
gas to dissipate, then repeat this ignition test.) The control knob can then be rotated
counterclockwise from “HIGH” to “LOW” to adjust the flame height progressively.
Repeat the ignition test for all burners. When installed properly, the flame will be
steady and quiet. It will also have a sharp, blue inner cone that will vary in length
proportional to the burner size.

NO

NO

NO

NO

NOTE

TE

TE

TE

TE

REFER TO THE USE AND CARE MANUAL FOR DETAILED INSTRUCTIONS.