Hose drainage, Cleaning and replacing the filter – Silvercrest SLE 420 A1 User Manual

Page 68

Advertising
background image

66 GB

7.5 Timer

• The timer can be combined with all

4modes.

• There are 12 switch-off times that can

be selected, from 1 to 12 hours.

• After the expiry of the time that has

been set, the device is shut down and
the timer function is terminated.

1. During operation, press the TIMER 19

button. The TIMER AKTIV LED 20 will
flash.

2. Use the arrow keys 18 to select a switch-

off time of between 1 to 12hours. The
selected time flashes in the display13
for 5seconds and is then saved.

• If you want to end the timer earlier than

the set time, press TIMER 19 twice or
switch the device off by pressing
STAND-BY 16.

8. Hose drainage

In the case of very damp rooms, it is often
more reasonable for the water not to be col-
lected in the water tank, but to be dis-
charged directly through a hose.

WARNING! During hose drainage, the de-
vice runs in continuous mode. This means
that the water collected must be able to
drain reliably, otherwise puddles will form
on the floor.

1. Figure C: use a screwdriver to remove

the fastener 21 on the rear.

2. Remove the plug 23.
3. Figure C: place the hose 22 included

in the box over the opening.

4. Place the device in a position where

the end of the hose is over a drain. It is
essential here that the open end of the
hose is lower down than the drain out-

let on the device (i.e. the hose must run
at a downward angle).

5. Switch the device on as described

above and select a mode.

6. If you wish to drain into the water

tank5 again, switch the device off, re-
move the hose 22, and replace the
plug 23 firmly over the opening.

9. Cleaning and

replacing the filter

The performance of the device also depends
on the cleanliness of the filter.
• The carbon filter 25 should be cleaned

every 2 weeks and replaced every
6months. Clean the filter by brushing
or vacuum suction.

• The normal plastic filter 24 should be

washed every 2 weeks.

1. Switch the device off and pull out the

mains plug 10.

2. Figure D: reach into the upper open-

ing of the grid 8 and pull it off.

3. Rotate grid 8 and press, if necessary

with both thumbs, in the middle of the
grid.

4. The plastic filter 24 and the carbon fil-

ter 25 come loose from the grid. Re-
move them from the grid 8.

5. Rinse out both filters with lukewarm wa-

ter. (The carbon filter 25 should be re-
placed after approx. 6 months.)

6. Allow both filters to dry completely.
7. Place the filters into the grid 8.
8. Place the grid onto the device.

NOTE: new carbon filters are available in
almost all household goods shops. The pads
just need to be cut to size.

GB_RP89301_Luftbefeuchter.fm Seite 66 Freitag, 19. April 2013 9:13 09

Advertising