51

GB

-

RH between 55% and 70%: the device
dehumidifies at its normal setting.

-

RH under 55%: no dehumidification,
only the fan is running.

NOTE: the relative humidity values of the
automatic system are not identical to the val-
ues HIGH/MID./LOW on the display 13.

Select this mode for continuous dehumidifi-
cation to a pleasant relative humidity of 55%.

CONTINUOUS
In the CONTINUOUS mode, you can set the
relative humidity in 5% increments to be-
tween 30% and 80%. The device dehumidi-
fies at a low level until the set value has been
reached, and then deactivates itself. When
the relative humidity rises again, the device
switches on again.
-

30 - 80%: setting for the desired relative
humidity in the room.

-

CO: the device dehumidifies continu-
ously.

Select this mode for continuous dehumidifi-
cation, or for dehumidification to a value
that you have set.

DRY CLOTHES
You can use this mode in order to dry damp
clothes or shoes faster. The device dehumid-
ifies at its highest setting. Shift the flap
valve1 of the air outlet in such a way that
the jet of air is directed towards the items of
clothing to be dried.

AIR CLEAN
No dehumidification takes place with this
mode. The room air is drawn in through the
filter in front of the air inlet, and is cleaned
there.

7.4 Water tank

• The water tank 5 has a holding capaci-

ty of 5 litres.

• The water level can be checked using

the inspection window 7 in the front.

• The device can only be operated with

the water tank in place.

• When the water tank 5 is full, the TANK

FULL LED 12 starts flashing. The device
switches off after a few seconds. An
alarm sounds for approx. 20 seconds.
The TANK FULL LED 12 flashes until the
tank has been emptied.

1. Figure A: in order to empty the water

tank 5, pull it out slightly on the left and
right-hand sides, and then carry it by
the handle 3.

2. Pour the water out and place the tank

back in the device.

7.5 Timer

• The timer can be combined with all

4modes.

• There are 12 switch-off times that can

be selected, from 1 to 12 hours.

• After the expiry of the time that has

been set, the device is shut down and
the timer function is terminated.

1. During operation, press the TIMER 19

button. The TIMER LED 20 will flash.

2. Use the arrow keys 18 to select a switch-

off time of between 1 to 12hours. The
selected time flashes in the display13
for 5 seconds and is then saved.

• If you want to end the timer earlier than

the set time, press TIMER 19 twice or
switch the device off by pressing
STAND-BY 16.

__RP89301_B5.book Seite 51 Sonntag, 21. April 2013 3:33 15

Advertising