Storage, Troubleshooting – Silvercrest SHSS 12 A1 User Manual

Page 10

Advertising
background image

7

SHSS 12 A1

GB

IE

Cleaning the rotary brush

The rotary brush t can become covered in
residues, such as hair, after a while. To remove this
dirt, you can remove the rotary brush t (Fig. 5).

1) Remove the fl oor nozzle from the handle.

2) Undo the screw on the underside of the fl oor

nozzle.

3) Remove the cover plate.

4) Press the holding pin to one side, for instance

with a screw driver, and lift out the rotary
brush t.

5) To replace the rotary brush t, fi rst push the

broad end onto the drive shaft so that the
rotary brush t hooks into place.

6) Then push in the other end so that the rotary

brush t clicks into place under the holding
pin.

7) Replace the cover plate and screw it down

fi rmly.

Fig. 5

Storage

When not in use, set the handle in an upright
position with the hand element 5 inserted and
the fl oor nozzle attached. The handle will lock
into place and stand upright on the fl oor nozzle.

For space-saving storage, you can fold the grip 0
by pressing the “Grip” release q.

Store the appliance in a dust-free and dry loca-
tion.

Troubleshooting

The appliance is not working.

The battery is not charged.

Connect the appliance to the charger p.

The appliance is defective.

In this case, contact the Customer Service.

The appliance is running but hardly
sucking up any dirt.

The battery is not suffi ciently charged.

Connect the appliance to the charger p.

The dirt container 9 is full.

Empty the dirt container 9.

The dust fi lter 7 is blocked.

Clean the dust fi lter 7.

The appliance will not charge.

The charger p is not correctly connected to the
socket/mains plug.

Check the connections of the charger p.

The charger p is defective.

In this case, contact the Customer Service.