Getting started, Removing part of the weight from the kitchen scale, Automatic or manual switch-off – Silvercrest Z29852A/Z29852B User Manual

Page 10: Volume units display mode

Advertising
background image

10 GB/IE

Getting started

Note for zero or tare setting:
a) If the total weight of all the

substances already placed on
the kitchen scale including the
weighing bowl is less than
200 g, then the LC display

4

shows the “0” icon

24

in

the bottom left corner. This
means that the kitchen scale
has been reset to zero = the
remaining weight capacity of
the kitchen scale remains
between 5000 and 5200 g.

b) If the total weight of all the

substances already placed
on the kitchen scale including
the weighing bowl is more
than 200 g, then the LC dis-
play

4

will show the “T”

icon

26

instead in the top

left corner. This means that the kitchen scale is
in tare mode = the remaining weight capacity
of the kitchen scale is 5000 g minus the weight
of substances already placed on the kitchen
scale.

Q

Removing part of the weight

from the kitchen scale

j

Place the weighing bowl

1

on the weighing

platform

6

.

Note: The container bowl must not exceed
200 g.

j

Press the On / Off / Zero button

5

to switch

on the kitchen scale

2

.

j

Wait until the LC display

4

stops and stabilizes

on 0 g

17

, 0:0.0 lb:oz

20

or 0 ml

18

or

0.0 fl’oz

19

, which will be the mode the kitchen

scale was in when it was last switched off.

j

Press the mode button

3

to set the weighing

mode

23

(preset to g or lb:oz).

j

Place the substance to be weighed into the
weighing bowl

1

to start the weighing process.

The LC display

4

shows the weight of the first

substance placed in the weighing bowl.

j

Press the On / Off / Zero button

5

to reset the

LC display

4

to zero.

j

Now remove the desired amount of substance
from weighing bowl

1

. The LC display

4

shows the weight of the substance removed
from the weighing bowl as a negative value.

Q

Automatic or manual switch-off

j

The kitchen scale switches itself off automatically
if it has not been used for 2 minutes.

j

Press the On / Off / Zero button

5

for longer

than 3 seconds to switch off the kitchen scale.

Q

Volume units display mode

j

Place the kitchen scale on
a solid, flat surface.

j

Press the On / Off / Zero
button

5

to switch on the

kitchen scale

2

.

j

Wait until the LC display

4

stops and stabilizes on

0 g

17

, 0:0.0 lb:oz

20

or

0 ml

18

or 0.0 fl’oz

19

,

which will be the mode the
kitchen scale was in when
it was last switched off.

j

Press the mode button

3

until milk

22

or water

21

appears as the volume
mode with the units as ml
or fl’oz.

j

Place a container for liquid
or the weighing bowl

1

on the weighing platform

6

.

j

Press the On / Off / Zero button

5

to set the

LC display

4

to zero (0 ml or 0.0 fl’oz). Pour

milk or water (as selected previously) into the
container.

j

The LC display

4

now automatically shows

the volume of liquid poured into the container,
either in ml or in fl’oz, depending on the setting.

j

Then press the mode button

3

to set the kitchen

scale to weighing mode again and read off the
equivalent weight of the liquid.