Under-Counter Ice Maker

E15IM60GSS designer series

High standards of quality at Electrolux Home Products, Inc. mean we are

constantly working to improve our products. We reserve the right to change

specifications or discontinue models without notice.

Electrolux Major Appliances, N.A.

USA

250 Bobby Jones Expressway

Augusta, GA 30907

1-877-4electrolux (1-877-435-3287)

electroluxicon.com

CANADA

5855 Terry Fox Way

Mississauga, ON L5V 3E4

1-800-265-8352

electroluxicon.ca

E15IM60GSS 01/09

© 2009 Electrolux Home Products, Inc.

Printed in the U.S.A.

Under-Counter Ice Maker Specifications

Product Weight – 100 Lbs.

Voltage Rating – 120V / 60 Hz / 15 Amps

Connected Load (kW Rating) @ 120 Volts = 0.48 kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded
for safe operation.)

Amps @ 120 Volts = 4.0 Amps

Electrical cable supplied.

Water supply and electrical power source required.

Always consult local and /or national electric & plumbing codes.

Unit is designed for either freestanding or built-in, under-counter
installation.

Built-in, under-counter installation does not require additional airspace
for top, sides or rear of unit.

Allow 1-1/2" minimum clearance behind unit for electrical, water
supply and drain connections.

Front grille MUST remain unobstructed for proper ventilation.

Can be installed using gravity drain or optional Drain Pump Kit (PN# EIMP60).

Drain lines must have 5/8" inside diameter, 1" drop per 48" (1/4" per
foot) of run and must not create traps.

Floor drain must be large enough to accommodate drainage from
all drains.

Recommended water pressure between 30 and 120 pounds
per square inch (psi).

Unit MUST be level for proper operation, and positioned on flat surface,
capable of supporting entire weight when fully loaded.

Leveling legs supplied to adjust height and level unit.

Can be installed outdoors, out of direct sunlight. Do NOT install behind
closed doors.

Do not position unit near any heat source or in direct sunlight to ensure
optimum performance. Surrounding air temperature must be at least
50° F but must not exceed 110° F.

Unit requires zero clearance when installing flush with cabinet or wall.

When installing against cabinet or wall that extends beyond front edge
of unit, 2-7/8" minimum handle clearance required to allow for 90° door
swing, providing sufficient interior access. (Door is field reversible for
right- or left-hand opening.)

Note: For planning purposes only. Refer to Product Installation Guide

on the web at electroluxicon.com for detailed instructions.

Optional Accessories

Drain Pump Kit – (PN # EIMP60).

Cleaning Kit – (PN # EIM41978).

34

1

/

8

"

Adjustable

to 35"

14

15

/

16

"

Front

Drain outlet

Water inlet

Power cord

3

3

/

8

"

7

3

/

8

"

1

5

/

8

"

2"

8

1

/

8

"

4

3

/

8

"

1

3

/

4

"

34

1

/

4

"

min.

24"
min.

15

1

/

8

"

90

°

90

°

Allow 1-1/2"

minimum clearance

behind unit for electrical,

water supply and drain

connections

23

1

/

4

"

Left

Water

inlet

Water

outlet

3

/

4

"

21

3

/

4

"

6

5

/

8

"

25

1

/

8

"

Top

Water supply
and drain
connections

14

15

/

16

"

3

/

4

"

38

1

/

8

"

Door in 90

°

open position

1

7

/

8

"