Jumper layout and configuration – Eurotech Appliances COM-1460 User Manual

Page 10

Advertising
background image

10

PC/104-Plus – COM-1460 Module

Jumper Layout and Configuration

The figure below shows the jumper layout of the COM-1460 module.

In the figure below, the jumpers are indicated as

JP

followed by the jumper's number, while pin 1 of every

three pin jumper is indicated by a red square pad.

JP3

JP2

JP5

JP4

JP1

Figure 2.

Jumpers on the COM-1460 module



The following jumpers are located on the module:



Three 2-pin jumpers which can be set as follows:

pin 1 and pin 2 not connected (which will be indicated as ‘Open’)
pin 1 connected to pin 2 (which will be indicated as ‘Closed’)



Two 3-pin jumpers which can be set as follows:

pin 1 connected to pin 2 (which will be indicated as ‘1-2’)
pin 2 connected to pin 3 (which will be indicated as ‘2-3’)
no pins connected (Open). This setting is not allowed





= 2-3

= 1-2

= Open

= Closed

= Open

Advertising