Insulation hot air outlet pipe wall crossed stove – MCZ Club AIR User Manual

Page 25

Advertising
background image

PELLET STOVES

Chapter 3

INSTALLATION AND USE MANUAL

page

25

Installation and assembly

Technical service - Rights reserved MCZ Group S.p.A. - Reproduction prohibited

E

F

3.3. CONNECTIONS OF HOT AIR DUCTS FOR

SUITE/CLUB/MUSA/NIMA AND TOBA COMFORT
AIR MODEL

Once the stove is in position, you can begin installation of the hot air

ducts.
Comfort Air stoves are provided with an air deflector E as standard. This

means that the rear flange for hot air outlet is connected to this

deflector, which allows the hot air to be directed to the right and left of

the room, in case the channelling of hot air is not desired.
If you wish to channel the hot air, the deflector E must be removed.

Connect the soundproofed connection F (optional) that makes the

output from square to round, and then make the various connections

with appropriate MCZ pipes and connections to divert the flow in more
hot air diffusers (120x120 mm nozzle). These ducts may also be walled

up. (SEE OPTIONALS)

The air outlet pipe can reach very high temperatures,

up to 200°C: it is therefore necessary to insulate it

properly with suitable materials, in those points

where it may come into contact with flammable

surfaces or that are affected by the temperature (e.g.

discolouration of paint, ducts for electric cables,

plasterboard, etc.); it is also necessary to protect

people and animals from voluntary or accidental

contact. In any case comply with the regulations and

laws in force in the region where the product is

installed.

It is advisable to provide insulation along the entire

route of the pipe to decrease dispersion and increase

the heat energy in the environment.


INSULATION

HOT AIR OUTLET

PIPE

WALL CROSSED

STOVE