PELLET STOVES

Chapter 5

INSTALLATION AND USE MANUAL

page

42

Menu structure

Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited

Esc Set
< Settings >

Mode:Auto Menu
Temp:22°C Fan:A

Esc Set
< Settings >

21.0°C 21.04
OFF

Esc OFF Set
Thermostat

Esc It Set
< Language >

Esc OFF Ok
Thermostat

Esc On Ok
Thermostat

Esc On Ok
Thermostat

5.4.6.1. Operating mode with external thermostat


In the SETTINGS - THERMOSTAT MENU select ON and exit the menu;

at this point, by selecting the AUTO operating mode (para 2.2) in the

place of the room temperature the word OFF will appear as the external

thermostat takes control of the stove. (contact open = temperature

achieved = stove on minimum; contact close = temperature not

achieved = stove on maximum)
In the condition of temperature achieved (thermostat contact open) the

stove does not shutdown but automatically modulates the flame to

minimum power; when the temperature is not achieved (thermostat

contact closed) the stove automatically modulates the flame to

maximum power.