Chapter 2

INSTALLATION AND USE MANUAL

page

11

Theoretical notions for installation

Technical service - Rights reserved MCZ S.p.A. - Reproduction prohibited

be protected by a grille, metal mesh or suitable guard, as long as

this does not reduce the area below the minimum.

be positioned in such a way as to be impossible to obstruct

It is not compulsory to connect the air intake directly

with the stove (so that it draws air directly from

outside), but it is essential at all events to ensure an

airflow of 50 cubic metres per hour by the use of a

hole of the dimensions given.
See standard UNI 10683 REV.

2.5. CONNECTION OF SMOKE DISCHARGE PIPE

When making the hole for the passage of the smoke discharge pipe, it

is necessary to take into account the possible presence of flammable

materials. If the hole will be going through a wall made of wood or any

other material which is sensitive to heat, the INSTALLER MUST first

of all use the special wall union (diam.13cm 13cm minimum) and

properly insulate the pipe of the stove that passes through it, using

adequate insulation materials (thickness 1.35cm with minimum thermal

conductivity of 0.07 W/m°K).
The same is true if the stove pipe must run through vertical or

horizontal stretches passing in proximity (min.20cm) to the heat-

sensitive wall
As an alternative we recommend the use of insulated pipe, which can

also be used on the outside to avoid condensation.
The combustion chamber works in low pressure. The smoke duct for

the discharge of fumes will also be under low pressure when connected

to an efficient flue pipe as directed.

IMPORTANT!

All 90 degree changes of direction in the flue pipe

must be fitted with suitable tee connectors to

allow the possibility of inspection. (see

accessories for pellet stove)

It is absolutely prohibited to fit a grille on the end

of the discharge pipe, because it could lead to

poor running of the stove.

FOR CONNECTION TO THE FLUE PIPE, NOT MORE

THAN 2-3 METRES OF HORIZONTAL PIPE MUST

BE USED AND NOT MORE THAN THREE 90°

CURVES MUST BE USED

IT IS ALSO ADVISABLE NOT TO EXCEED 6

METRES IN LENGTH WITH THE PIPE Ø 80 mm

THE TUBE Ø 80 mm IS NEEDED ONLY TO

CONNECT THE FLUE PIPE AND CANNOT ITSELF

BE CONSIDERED AS A FLUE PIPE. The flue pipe

has the following characteristics described in

subsequent paragraphs

Example of installation of PowerSystem

Connection of smoke discharge pipe

Diagram