Maintenance and cleaning

Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited

F

G

6. MAINTENANCE AND CLEANING

Only a proper maintainance and cleaning of the product can assure you

the correct functionality and a safe use of your stove.

ATTENTION!

All the cleaning operations of all parts must be

performed with the product completely cold and the

plug disconnected.

Disconnect the product from the 230V power supply

before performing any maintenance operation.

The product requires little maintenance if used with certified

high quality pellets.

6.1. DAILY OR WEEKLY CLEANING PERFORMED BY
THE USER

6.1.1.

Brazier cleaning

Before ignition, always clean the “T” brazier and remove any ash or

incrustation from it that might obstruct the air flow holes, paying

attention to hot ash. In the case of ignition failure, or if fuel in the tank

runs out, unburned pellets may accumulate in the brazier. Always

empty the residue in the brazier before each start-up. Only if ash is

completely cold may a vacuum cleaner be used to remove it. In this

case, use a suitable vacuum cleaner to remove small sized particles.

REMEMBER THAT ONLY A CORRECTLY POSITIONED

AND CLEAN BRAZIER CAN GUARANTEE THE IGNITION

AND OPTIMAL OPERATION OF YOUR PELLET

PRODUCT. IN CASE OF FAILED IGNITION AND AFTER

ANY OTHER LOCK STATE OF THE PRODUCT, IT IS

ESSENTIAL TO EMPTY THE BRAZIER BEFORE

PROCEEDING TO RESTART.


IF IGNITION FAILS (A01), IT IS IMPORTANT TO

REMOVE THE PELLETS LEFT IN THE BRAZIER BEFORE

REPEATING THE IGNITION OPERATION.

For the brazier to be cleaned properly, remove it from its housing

completely and thoroughly clean all the holes and the grate on the

bottom. If good quality pellets are used, you will normally only need to

use a brush to restore the optimal operating conditions of the

component.

6.1.2.

Ash tray cleaning

Remove and empty the “G” ash tray. Wipe away any residual ash

before reinserting the tray. Your experience and the quality of the

pellets will determine the ash tray cleaning frequency. However, it is

recommended not to exceed 2 or 3 days.

Example of clean grate

Cleaning the ash collection compartment

Example of dirty grate