Marwin Valve 5801F Series Fire Safe Flanged Valves User Manual

Scope, Applicability, Caution

Advertising
background image

3170 Wasson Road • Cincinnati, OH 45209 USA

Phone 513-533-5600 • Fax 513-871-0105

[email protected] • www.marwinvalve.com

I & M 5801/6801 Series

Installation & Maintenance Instructions for

Marwin 5801/6801 Series Floating Ball Valves

Warning: Marwin Valve Ball Valves must only be used, installed and repaired in accordance with these Installation &
Maintenance Instructions. Observe all applicable public and company codes and regulations. In the event of leakage
or other malfunction, call a qualified service person; continued operation may cause system failure or a general hazard.

Please read these instructions carefully!

Your Marwin Valve product will provide you with long,
trouble-free service if it is correctly installed and main-
tained. Spending a few minutes now reading these in-
structions can save hours of trouble and downtime later.
When making repairs, use only genuine Marwin Valve
parts, available for immediate shipment from the factory.

Scope

This manual is intended as a guide to assist customers
in the storage, installation, and maintenance of Marwin
5801 and 6801 Series Ball Valves. Subsequent additions
or special instructions will be provided for special ball
valves, critical service, or customer requirements.

Applicability

This manual is applicable to the following Marwin ball
valves: ½” - 8” 5801F, ½” - 8” 6801F, and 1” - 8” 5801R.
Valve identification is given on a nameplate attached to
the pipe flange outside diameter.

Caution

Valve pressure ratings are based on many vari-

1.

ables, including valve series and size, as well as
body, seat and bolt material. Verify that application
does not exceed the pressure or temperature rat-
ing on the nameplate.
ALWAYS

2.

depressurize the line with the valve in the

OPEN position before disassembly.
Wear protective equipment and take appropriate

3.

precautions to safeguard against injury caused by
the discharge of trapped fluids.
Use only Marwin recommended spare parts for

4.

maintenance.
To ensure safety and maintain warranty, never

5.

modify valve in any way without prior approval from
Marwin.

Storage

Silicone free oil is used as lubrication on all internal sur-
faces. This may be removed with a solvent if found ob-
jectionable. All valves are adequately packed in a strong
cardboard case in such a way as to avoid any possible
damage during transport and storage.

CAUTION: If ball valves are not destined for immedi-
ate use, the following precautions should be taken:

If possible, leave the ball valves in their packing

1.

cases during the period of storage.
Ball valves must remain in open position during this

2.

time.
In order to prevent damage, protective plastic cov-

3.

ers on valve ends should not be removed until im-
mediately prior to installation.
It is advisable to store the valves in waterproof

4.

conditions. Ball valves should be protected to safe-
guard against humidity, moisture, dust, dirt, sand,
mud, salt spray, and seawater.
All valves complete with actuators are to be stored

5.

in dry conditions.
Valves to be stored for a long period of time should

6.

be checked by the quality control personnel every
six months; every three months when valves are
automated.

Maintenance During Storage Period

Internal surface should be inspected to check for

dust or other foreign objects.
Rust or dust must be removed by cleaning with

proper solvent.
After cleaning, ball valves must be lubricated with

Advertising
This manual is related to the following products: