3024c actuator, Instruction manual – Emerson Process Management 3024C User Manual

Page 4

Advertising
background image

3024C Actuator

Instruction Manual

Form 5760

March 2007

4

Table 3. Additional Specifications (Action Air-to-Open)

Size

Spring Set/

Quantity

Travel

Spring Range

Effective Diaphragm Area

(Note 1)

Maximum Output Thrust

(Maximum Actuator Stem

Force) (Note 2)

Quantity

mm

Inch

Bar

Psig

cm

2

Inches

2

N

Lb

217/3

0.5 - 1.3

7 - 19

170

26.4

780

170

30

217/3
218/5

16

-

1.4 - 2.2

20 - 32

170

26.4

2360

530

30

218/5
218/7

16

2.0 - 3.1

29 - 45

170

26.4

3360

760

217/3

0.3 - 1.3

4 - 19

175

27.1

550

120

30E

217/3
218/5

-

0.75

1.2 - 2.2

17 - 32

175

27.1

2180

490

30E

218/5
218/7

0.75

1.8 - 3.1

26 - 45

175

27.1

3110

700

219/3

0.6 - 1.4

9 - 20

410

63.6

2450

550

34

219/3
212/5

16

-

1.1 - 1.9

16 - 28

410

63.6

4610

1040

34

212/5
212/7

16

1.6 - 2.7

23 - 39

410

63.6

6560

1480

219/3

0.4 - 1.4

6 - 20

420

65.1

1880

420

34E

219/3
212/5

-

0.75

1.0 - 1.9

15 - 28

420

65.1

4120

930

34E

212/5
212/7

0.75

1.4 - 2.7

20 - 39

420

65.1

5870

1320

212/3

0.4 - 1.3

6 - 19

450

69.8

1880

420

40

212/3
213/6

32

-

0.8 - 1.8

12 - 26

450

69.8

3640

820

40

213/6
214/7

32

1.2 - 2.4

17 - 35

450

69.8

5530

1240

212/3

0.5 - 1.3

7 - 19

440

68.2

2200

500

212/3
213/6

-

1.125

0.9 - 1.8

13 - 26

440

68.2

3970

890

213/6
214/7

1.125

1.3 - 2.4

19 - 35

440

68.2

5920

1330

213/4

0.4 - 1.1

6 - 16

410

63.6

1560

350

40E

213/4
214/5

-

1 5

0.7 - 1.6

10 - 23

410

63.6

3010

680

40E

214/5
214/7

1.5

1.0 - 2.3

15 - 33

410

63.6

4270

960

213/4

0.2 - 1.2

3 - 17

440

68.2

1060

240

213/4
214/5

-

2

0.5 - 1.8

7 - 26

440

68.2

2390

540

214/5
214/7

2

0.8 - 2.5

12 - 36

440

68.2

3400

760

221/8

0.8 - 1.7

12 - 25

940

146

7790

1750

45

221/8

221/12

32

-

1.2 - 2.5

17 - 36

940

146

11,700

2630

45

221/12
223/12

32

1.6 - 3.2

23 - 46

940

146

14,700

3300

221/8

0.9 - 1.7

13 - 25

910

141

8350

1880

221/8

221/12

-

1.125

1.4 - 2.5

20 - 36

910

141

12,500

2810

221/12
223/12

1.125

1.7 - 3.2

25 - 46

910

141

15,700

3530

221/8

0.7 - 1.6

10 - 23

870

135

6150

1380

45E

221/8

221/12

-

1.5

1.1 - 2.4

16 - 35

870

135

9230

2080

45E

221/12
223/12

1.5

1.3 - 3.1

19 - 45

870

135

11,500

2590

221/8

0.5 - 1.7

7 - 25

940

146

4740

1070

221/8

221/12

-

2

0.8 - 2.6

12 - 38

940

146

7110

1600

221/12
223/12

2

0.9 - 3.2

13 - 46

940

146

8800

1980

Note 1: Effective diaphragm area at 0% valve travel from seat.