-Based Program Control

The Universal Switcher Control Program is compatible with
Windows 3.1/3.11, Windows 95/98, Windows NT, Windows
ME, and Windows 2000 and provides remote control of the
input selection for each output (including audio breakaway)
and audio gain and attenuation adjustments.

Updates to this program can be downloaded from the Extron
Web site (http://www.extron.com).

Installing the software

The program is contained on a single 3.5” diskette and can be
run from the floppy drive, or it can be installed and run from
the hard drive. To install the software on the hard drive, run
setup.exe from the floppy disk and follow the screen
instructions.

By default, the Windows installation creates a C:\UNIVSW
folder and places two icons (Universal Switcher Control
Program and Universal Switcher Help) into a group named
“Extron Electronics”.

Using the software

1

.

To run the software, double click on the
Universal Switcher Control Program icon in
the Extron Electronics program group.

2

.

In the Comm Port Selection window (figure 4-2), click on
the comm port that is connected to the MMX’s RS-232 port.

Figure 4-2 — Universal Switcher Comm Port
Selection window

4-7

4-6

Command

ASCII Command

Response

Additional description

(host to switcher)

(switcher to host)

V

iew

V

ideo output tie

X3

%

X2

V

ideo output tied to

X2

input (0* thr

ough max.)

Audio output tie

X3

$

X2

Audio output tied to

X2

input

(0* thr

ough max.)

Gain for input

X1

G

X4

Input audio gain/attenuation =

X4

(-18 to +24)

* 0 = output deselected.

Setting input audio gain/attenuation

Set gain (+dB)

X1

*

X5

GI

N

X1

•AUD

X4

Set gain for input

X1

to

X4

dB.

Example

:

4*3G

IN4•AUD=3

Set gain for input 4 to 3dB.

Set attenuation (-dB)

X1

*

X6

gI

N

X1

•AUD=

X4

Set attenuation for input

X1

to

X4

dB.

Incr

ement gain

X1

+G

IN

X1

•AUD

X4

Incr

ement gain for input

X1

by +1dB.

Decr

ement gain

X1

-G

IN

X1

•AUD

X4

Decr

ement gain for input

X1

by -1dB.

Fr

ont panel executive mode

Lock fr

ont panel

1

X/x

Exe

1

Lock fr

ont panel

Unlock fr

ont panel

0

X/x

Exe

0

Unlock fr

ont panel

Lock status

X/x

X9

F

ront panel lock status =

X9

(0= of

f and 1=on).

Reset commands

Reset all audio gains to 0dB

Esc

ZA

Zpa

Resets all audio gains to 0dB

Unmute all audio

Esc

ZZ

Zpz

Unmutes all audio

Unmute all video

Esc

ZB

Zpb

Unmutes all video

System r

eset to factory default

Esc

ZXXX

Zpx

Resets switcher to factory default settings.

Miscellaneous commands

Information r

equest

I/i

V

1*

X1

•A1

*

X1

•V

2*

X1

•A

2*

X1

Vmt1*

X9

Amt1*

X9

Vmt2*

X9

A

mt2*

X9

QVER

X6

Request part number

N/n

Nxx-xxx-xx

xx-xxx-xx = MMX part number (see

Appendix

A

).

Query softwar

e version

Q/q

QVER

X19

Contr

oller softwar

e version

X19

.

Advertising