Multi-Contact MA223 User Manual

Multi-Contact Relay

Advertising
background image

Advanced Contact Technology

www.multi-contact.com

1 / 8

PV-ADBP3/.../GWD

PV-ADBP3/.../GWD

MC-K.../PV-ADBP3/.../GWD

MC-K.../PV-ADSP3/.../GWD

MA223 (es_en)
Instrucciones de montaje

MA223 (es_en)
Assembly instructions

Conector hembra empotrable en panel o caja
PV-ADBP3/.../GWD
Conector macho empotrable en panel o caja PV-
ADSP3/.../GWD
Conector hembra empotrable en panel o caja
con el cable MC-K.../PV-ADBP3/.../GWD
Conector macho empotrable en panel o caja con
el cable MC-K.../PV-ADSP3/.../GWD

PV-Female panel receptacle PV-ADBP3/.../GWD
PV-Male panel receptacle PV-ADSP3/.../GWD
PV-Female panel receptacle with cable
MC-K.../PV-ADBP3/.../GWD
PV-Male panel receptacle with cable
MC-K.../PV-ADSP3/.../GWD

Índice

Instrucciones de seguridad ........................................................2

Herramientas necesarias ...........................................................3

Cables de conexión ...................................................................3

Preparación del cable ...............................................................4

Conexiones por engarce ............................................................4

Engarce ....................................................................................4

con alicates de engarce PV-CZM-16100A .............................4

Montaje de los conectores empotrables ...................................5

Disposición del cable .................................................................6

Conexión ...................................................................................6

Content

Safety Instructions ......................................................................2

Tools required ............................................................................3

Connecting lead ........................................................................3

Cable preparation ......................................................................4

Crimp connections ....................................................................4

Crimping ....................................................................................4

with crimping pliers PV-CZM-16100A ....................................4

Assembly of panel receptacles ..................................................5

Cable routing .............................................................................6

Engagement ..............................................................................6

Conector hembra empotrable en panel o caja
Female panel receptacle

Conector macho empotrable en panel o caja
Male panel receptacle

con el cable / with cable

con el cable / with cable

Etiqueta adhesiva

Sticker

Datos técnicos

Technical data

Sistema de conectores

Connector system

Ø 3mm

Tensión nominal

Rated voltage

1000V DC (IEC)

Corriente nominal

Rated current

20A (2,5mm

2

, 4mm²)

30A (6mm²)

Tensión de control

Test voltage

6kV (50Hz, 1min.)

Rango de temperatura ambiente

Ambient temperature range

-40°C...+85°C (IEC)

Temperatura límite superior

Upper limiting temperature

105°C (IEC)

Tipo de protección, enchufado

desenchufado

Degree of protection, mated

unmated

IP65
IP2X

Categoría de sobretensión / Grado de suciedad

Overvoltage category / Pollution degree

CATIII / 2

Resistencia de contacto de los conectores

Contact resistance of plug connectors

0,5mΩ

Clase de protección

Safety class

II