RISCO Group WL Shock & Contact Detector WL T62 User Manual

Wl t62, Wireless shock & contact detector

Advertising
background image

WL T62

Wireless

Shock & Contact

Detector

Installation

Instructions

UK Tel: +44-(0)-161-655-5500
E-mail: [email protected]

ITALY Tel: +39-02-66590054
E-mail: [email protected]

SPAIN Tel: +34-91-490-2133
E-mail: [email protected]

FRANCE Tel: +33-164-73-28-50
E-mail: [email protected]

BELGIUM Tel: +32-2522-7622
E-mail: [email protected]

U.S.A Tel: +1-631-719-4400
E-mail: [email protected]

BRAZIL Tel: +55-11-3661-8767
E-mail: [email protected]

CHINA (Shanghai)
Tel: +86-21-52-39-0066
E-mail: [email protected]

CHINA (Shenzhen)
Tel: +86-755-82789285
E-mail: [email protected]

POLAND Tel: +48-22-500-28-40
E-mail: [email protected]

ISRAEL Tel: +972-3-963-7777
E-mail: [email protected]

RISCO Group Limited Warranty

RISCO Group and its subsidiaries and affiliates ("Seller") warrants its products
to be free from defects in materials and workmanship under normal use for 24
months from the date of production. Because Seller does not install or connect
the product and because the product may be used in conjunction with products
not manufactured by the Seller, Seller cannot guarantee the performance of the
security system which uses this product. Seller's obligation and liability under
this warranty is expressly limited to repairing and replacing, at Seller's option,
within a reasonable time after the date of delivery, any product not meeting the
specifications. Seller makes no other warranty, expressed or implied, and makes
no warranty of merchantability or of fitness for any particular purpose

.

In no case shall seller be liable for any consequential or incidental damages for
breach of this or any other warranty, expressed or implied, or upon any other
basis of liability whatsoever

.

Seller's obligation under this warranty shall not include any transportation
charges or costs of installation or any liability for direct, indirect, or consequential
damages or delay

.

Seller does not represent that its product may not be compromised or
circumvented; that the product will prevent any personal injury or property loss
by burglary, robbery, fire or otherwise; or that the product will in all cases provide
adequate warning or protection

.

Seller, in no event shall be liable for any direct or indirect damages or any other
losses occurred due to any type of tampering, whether intentional or
unintentional such as masking, painting or spraying on the lenses, mirrors or any
other part of the detector

.

Buyer understands that a properly installed and maintained alarm may only
reduce the risk of burglary, robbery or fire without warning, but is not insurance
or a guaranty that such event will not occur or that there will be no personal
injury or property loss as a result thereof

.

Consequently seller shall have no liability for any personal injury, property
damage or loss based on a claim that the product fails to give warning.
However, if seller is held liable, whether directly or indirectly, for any loss or
damage arising under this limited warranty or otherwise, regardless of cause or
origin, seller's maximum liability shall not exceed the purchase price of the
product, which shall be complete and exclusive remedy against seller

.

No employee or representative of Seller is authorized to change this warranty in
any way or grant any other warranty

.

WARNING: This product should be tested at least once a week

.

FCC NOTE (for 433MHz versions only):

This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
a) Reorient or relocate the receiving antenna.
b) Increase the separation between the equipment and receiver.
c) Connect the equipment to an outlet on a circuit different from that to which the receiver

is connected.

d) Consult the dealer or an experienced radio/TV technician.

FCC Warning

The manufacturer is not responsible for any radio or TV interference caused by
unauthorized modifications to this equipment. Such modifications could void the user's
authority to operate the equipment.
FCC ID: JE4RWT71X433

RTTE Compliance Statement

Hereby, RISCO Group declares that this equipment is in compliance
with the essential requirements and other relevant provisions of Directive
1999/5/EC.
For the CE Declaration of Conformity please refer to our website:

www.riscogroup.com.


© RISCO Group 04/11

5IN1323

C

GENERAL DESCRIPTION

The WL T62 combines both a Shock detector and a
Door/Window Contact detector in a single casing for internal
use that provides reliable 24-hour perimeter protection.
The detector employs an advanced digital microprocessor to
analyze the vibration signal received from the piezo electric
sensor.
The WL T62 has a reed switch for protection against opening
doors and windows, and against any attempt to tamper the
detector using large magnets.
This detector operates in conjunction with RISCO's
programmable receivers and is powered by a standard 3-volt
lithium battery.


MAIN FEATURES

• Digital Microprocessor with Intelligent Digital Signal

Processing

• Tri-color LED enables accurate and reliable calibration, with

“over-sensitive” and “under-sensitive” indications

• Gross attack detections
• Shock and Contact detection reported to separate zones in
the receiver
• Detects attempts of magnet tampering (0.3T)
• Encapsulated bi-morph piezo electric sensor
• Dual stage adjustment potentiometer
• Back & Cover tamper protection

• Operates up to 300m (1000 ft) range (LOS)

• Uses one of more than 16 million addresses codes

• Hold on/off

• Fully supervised

DIPSWITCHES

Dipswitch Description

1

Used to enable or disable LED

Dipswitch Position

LED

ON

(Default)

Enabled

OFF

Disabled

2

Used to determine the sensitivity of the Shock detector

Dipswitch Position

Sensitivity

ON

(Default)

High

OFF

Low

NOTE: For fine tuning use the sensitivity trimmer.

3

Used to determine the detector HOLD status (Contact Only)

Dipswitch Position

Hold Status

ON

There will be 2.5 minutes dead time between the
alarm detection transmissions. (Restore
messages will be sent immediately)

NOTE: Only one alarm message is transmitted in any
2.5 minute period.

OFF

(Default)

No dead time between alarm detection
transmissions (the unit transmits after each
detection)

4

Used to enable or disable the Contact

Dipswitch Position

Internal Reed Switch (S1)

ON

Disable

OFF

(Default)

Enable

5

Used to enable or disable the anti-sabotage function (Contact Only)

Dipswitch Position

Anti-Sabotage Reed Switch (S2)

ON

Enable

OFF

(Default)

Disable

6

Used to determine the detector RF power
Dipswitch Position

RF Power Transmission

ON

Low

OFF

(Default)

High

LED INDICATION

After each detection, the LED turns ON momentarily.
On Low Battery condition, the LED will blink during each transmission.

GREEN

Indicates an alarm condition

for Shock detection

RED

• Under-Sensitive indication of Shock detector
• Indicates an alarm condition for Contact detection
• Tamper indication
• Write message

ORANGE

Over-Sensitive indication

for Shock detection

FRONT COVER REMOVAL

Remove the front cover as described in Figure 2.

TRANSMITTER/RECEIVER COMMUNICATION SET UP

The transmitter must identify itself to the system’s receiver by writing its coded
messages into the receiver’s address memory. The receiver must identify the
Shock detector and the Contact detector separately. This is accomplished by
performing the following steps:
a. Set the receiver to the Write Mode (follow the receiver’s instructions).
b. Remove the battery from the insulation material and reinsert it into the

transmitter, paying attention to the polarity (see Fig. 3).

c. Send a separate Write message to each detector. Use Dipswitch 3, as

described in the table below, to choose a detector. To program the ID of a
Shock detector set the Dipswitch to the OFF position and send a Write message
by pressing both tamper buttons for at least 3 seconds.

Detector

Dipswitch 3

Restore

Shock detector

OFF (Default)

No

Contact Detector

ON

Yes

d. To program the ID of the Contact detector set Dipswitch 3 to ON and send a

Write message by pressing both tamper buttons for at least 3 seconds.

e. Set the receiver to the Normal mode.
f. Verify that the receiver has identified each of the detectors by generating a

tamper signal (by momentarily closing and opening both tampers). The tamper
message will be sent twice, once for each detector.

NOTE: If for any reason it is necessary to re-send a write message, press both of the
tamper buttons (back and cover) for at least 3 seconds.

INSTALLATION INSTRUCTIONS

Considerations for wireless communication
a. For best wireless communication, place the unit at the highest possible

position.

b. Temporarily attach the unit to this point using two sided adhesive tape.
c. Generate an Alarm or Tamper signal and verify that the receiver has

received the signal. If the signal is not detected, reposition the transmitter
and try again.

Considerations for shock detection

1. Select the intended position for installation, ensuring the surface is clean

and clear of any irregularities. Refer to Table 1 for details about
detection ranges for the different surface types.

2. Set the detector’s sensitivity as follows, using the sensitivity trimmer:

i. With the unit set for normal operation, use a suitable instrument to

bang or tap the protected area.

ii. If the sensitivity needs adjustment, use a screwdriver to adjust the

trimmer (turn the trimmer control clockwise to increase sensitivity
or counter-clockwise to reduce sensitivity).
iii. Repeat steps i and ii until the desired sensitivity level is achieved.
If required, you can set Dipswitch 2 to OFF to reduce sensitivity
range.

3. Close the front cover.

Table 1: Typical Detection Range

Surface

Concrete

Brick Wall

Steel

Glass Wood Plywood

Radius

1.5m

5ft

2.5m

8.2ft

3m

10ft

3.5m

11.5ft

3.5m

11.5ft

4m

13ft

The above values are typical and are subject to practical testing, which must be
performed for each installation. In some environments, these values may differ
from the values listed above.

Considerations for magnet installation

a. Install the WL T62 in a place that enables you to install the magnet in

parallel to it (for example: door frame).

b. Install the magnet on the right side of the WL T62 as indicated in Figure 6.

NOTES:

• Maximum distance of the magnet from the detector is 20mm (0.7inch).
• Position the magnet as close as possible to the same plane level as the back surface of
the WL T62.
• The mark on the magnet's plastic case should be opposite to the mark on the detector's
case.
• Placing the magnet on the wrong side of the WL T62 will cause a tamper alarm signal

.

FINAL MOUNTING

Separate the back part of the transmitter (Fig. 4), and mount all the parts in
place (Fig. 5).

SPECIFICATIONS

ELECTRICAL
Battery Type:

CR123 3V Lithium Battery

Current Consumption:

10µA standby

Frequency:

433.92 / 868.65 MHz

Supervision Transmission:

868.65 MHz model: every 15 minutes
433.92 MHz model: every 65 minutes

Modulation Type:

ASK

Battery Life:

3 years depends on usage

PHYSICAL
Size:

81 x 35 x 32 mm (3.2 x 1.37 x 1.27 in.)

ENVIRONMENTAL
RF immunity:

According to EN-50130-4

Operating temperature:

0°C to 55°C (32°F to 131°F)

Storage temperature:

-20°C to 60°C (-4°F to 140°F)

Maximum humidity:

95% non-condensing

Specifications are subject to change without prior notice.
Should any questions arise please contact your supplier.

ORDERING INFORMATION

Model Description
WL T62

WL Shock & Contact, 433/868 MHz, White/Brown

DESCRIPTION GENERALE

Le WL T62 combine un détecteur de choc et un détecteur
d'ouverture sans fil dans un même boîtier destiné à une
utilisation intérieur, et qui offre une protection fiable 24h/24 du
p

érimètre couvert. Grâce à son microprocesseur numérique

de pointe, le d

étecteur analyse tout signal de vibration qui lui

est envoy

é par le capteur piézo-électrique.

Le WL T62 intègre un contact reed pour une protection contre
l'ouverture des portes et des fenêtres, et contre le sabotage
du détecteur en utilisant un aimant puissant.
Aliment

é par une pile au lithium de 3V standard, il fonctionne

en combinaison avec les r

écepteurs programmables de

RISCO.


CARACTERISTIQUES PRINCIPALES

• Microprocesseur avec traitement intelligent du signal

num

érique

• Diode

électroluminescente tricolore (LED) pour un calibrage

pr

écis et fiable, avec indications "d'excès" et "d'insuffisance"

de sensibilit

é

• D

étection d'attaques brutales

• Détection de choc et d'ouverture gérées sur 2 zones
différentes du récepteur
• Détecte les tentatives de sabotage par aimant (0.3T)
• Capteur pi

ézo-électrique bimorphe intégré

• Potentiom

ètre à double réglage

• Autoprotection à l'arrachement et à l'ouverture
• Portée allant jusqu'

à 300 m. (1000 ft.) (Champ libre)

• Utilise un code d'adresse parmis plus de 16 millions
• Information type maintenue (On/Off)
• Dur

ée de vie étendue de la pile

• Enti

èrement supervisé

DIPSWITCHES

Dipswitch Description

1

Utilisé pour activer ou désactiver la LED

Position du DIP

LED

ON

(par défaut))

Activé

OFF

Désactivé

2

Utilisé pour déterminer la sensibilité du détecteur de choc

Position du DIP

Sensibilité

ON

(par défaut)

Elevée

OFF

Faible

NOTE : Pour un réglage fin, utiliser le potentiomètre de sensibilité.

3

Sert à déterminer l'état de MAINTIEN du détecteur (Contact seulement)

Position du DIP

Etat de Maintien

ON

Un temps mort de 2 min. 30 s'écoulera entre les
detections d'alarme transmises (Les

messages de

rétablissement seront envoyés immédiatement)
REMARQUE : Un seul message d'alarme est émis par
intervalle de 2 min. 30.

OFF

(par défaut)

Pas de temps mort entre les détections d'alarme
transmises (l'appareil émet après chaque
détection)

4

Utilisé pour activer ou désactiver le contact magnetique

Position du DIP

Contact reed Interne (S1)

ON

Désactivé

OFF

(par défaut)

Activé

5

Utilisé pour activer ou non la fonction anti-sabotage (Contact seulement)

Position du DIP

Contact reed Anti-Sabotage (S2)

ON

Activé

OFF

(par défaut)

Désactivé

6

Sert à déterminer la puissance de transmission RF.
Position du DIP

Transmission RF

ON

Faible

OFF

(par défaut)

Elevée

INDICATIONS LED

Apr

ès chaque détection, la diode LED s'allume momentanément.

Lorsque la pile est faible (batterie faible) – la diode LED clignote

à chaque

transmission.

VERTE

Indique une condition d'alarme pour la détection de choc

ROUGE

• Indique une insuffisance de sensibilit

é pour la détection de choc

• Indique une condition d'alarme pour la détection d'ouverture
• Indication de sabotage
• Message d'écriture

ORANGE

Indique un exc

ès de sensibilité

pour la détection de choc

RETRAIT DU COUVERCLE FRONTAL

Enlever le couvercle comme décrit en figure 2.

PARAMETRAGE DE LA COMMUNICATION TRANSMETTEUR/

RÉCEPTEUR

Le transmetteur doit s'identifier aupr

ès du récepteur du système en inscrivant ses

messages cod

és dans le registre d'adresses du récepteur. Ce dernier voit le

détecteur de choc et le détecteur d'ouverture s

éparément. Cette opération

s'accomplit en ex

écutant les étapes suivantes :

a. R

églez le récepteur en mode écriture (suivez pour cela les instructions

correspondantes).

b. Retirez la pile de sa protection isolante et r

éinsérez-la dans le transmetteur en

respectant la polarit

é indiquée (cf. fig. 3).

c. Envoyez un message d'écriture de chaque détecteur s

éparément. A l'aide du

Dipswitch 3, s

électionnez un détecteur selon les instructions du tableau ci-

dessous. Pour programmer l'ID du détecteur de choc, r

églez le Dipswitch en

position OFF et envoyez un message d'écriture en appuyant sur les deux
contacts d'autoprotection pendant au moins 3 secondes.

Détecteur

Dipswitch 3

Restauration

Détecteur de choc

Arrêt (OFF) (par défaut)

Non

Détecteur d'ouverture

Marche (ON)

Oui

d. Pour programmer l'ID du détecteur d'ouverture, réglez le Dipswitch 3 en position

ON et envoyez un message d'écriture en appuyant sur les deux contacts
d'autoprotection pendant au moins 3 secondes.

e. R

églez le récepteur en mode normal.

f. V

érifiez que chaque détecteur a bien été identifié par le récepteur : pour cela,

g

énérez un signal d'autoprotection (en fermant et ouvrant momentanément les

deux AP). Le message d'AP sera envoyé 2 fois, pour les 2 détecteurs.

REMARQUE : si pour une raison quelconque, il s'avère nécessaire de renvoyer un
message d’

écriture, il suffit pour cela d'appuyer simultanément sur les deux contacts

d'autoprotection (arri

ère et couvercle) pendant au moins 3 secondes.

INSTRUCTIONS D'INSTALLATION

Considérations pour la communication sans fil

a. Pour une meilleure communication, placez l'appareil le plus haut

possible.

b. Fixez provisoirement l'appareil en ce point en utilisant de l'adh

ésif double

face.

c. Générer un signal d'alarme ou d'AP et v

érifiez que le récepteur a bien

re

çu le signal. Si le signal d'alarme n'a pas été détecté, repositionnez le

transmetteur et r

éessayez.

Considérations pour la détection de choc

1. Choisissez l'endroit souhaité pour l'installation, en vous assurant que la

surface est bien propre et nette de toutes asp

érités. Se reporter au

tableau 1 pour consulter les port

ées de détection selon les différents

types de surfaces.

2. Ajuster la sensibilit

é du détecteur comme suit, en vous servant du

potentiomètre de sensibilit

é :

(i) L'appareil

étant en mode de fonctionnement normal, feignez, à l'aide

d'un instrument adapt

é, une intrusion (en cognant ou frappant) au

sein de la zone prot

égée.

(ii) Si la sensibilit

é requiert un ajustement, ajustez le réglage à l'aide d'un

tournevis (dans le sens des aiguilles d'une montre pour augmenter la
sensibilit

é, et dans le sens inverse pour la réduire).

(iii) Renouvelez les

étapes (i) et (ii) jusqu'

à obtenir le niveau de

sensibilit

é souhaité. Si nécessaire, vous pouvez mettre le Dipswitch

2 sur OFF pour réduire la sensibilité.

3. Fermez le couvercle frontal.

Tableau 1 : Port

ées typiques de détection

Surface

Béton

Mur de briques

Acier

Verre

Bois

Contreplaqué

Rayon

1,5 m

2,5 m

3m

3,5 m

3,5 m

4m

Les valeurs indiqu

ées ci-dessus sont des valeurs typiques et doivent être

soumises

à un test pratique à réaliser à chaque installation. Dans certains

environnements, ces valeurs peuvent

être différentes de celles du tableau ci-

dessus.

Considérations pour l'installation d'un contact magnétique

a. Installer le WL T62 à un endroit qui vous permet d'installer l'aimant en

parallèle à ce dernier (par exemple : cadre de porte).

b. Installer l'aimant sur le côté droit du WL T62 comme indiqué en Figure 6.

NOTES :

• La distanceMaximum entre l'aimant et le détecteur est de 20mm.
• Positionner l'aimant pour que sa surface de pose soit la plus proche possible de la
surface de pose du WL T62.

La marque faite sur le boîtier en plastique de l'aimant doit se trouver à l'opposé de la

marque faite sur le boîtier du détecteur

.

• Posistionner l'aimant du mauvais côté du WL T62 provoquera un signal d'AP.

ASSEMBLAGE FINAL

S

éparez la partie arrière de l’émetteur (Fig. 4), et montez toutes les pièces

(Fig. 5).

SPECIFICATIONS

ELECTRIQUES
Type de batterie :

pile lithium 3V CR123

Consommation

électrique :

10µA en veille

Fr

équence :

433.92 / 868.65 MHz

Transmission de supervision :

Modèle 868.65 MHz : toutes les15 minutes
Modèle 433.92 MHz : toutes les 65 minutes

Type de modulation :

ASK

Dur

ée de vie de la pile :

3 ans selon utilisation

PHYSIQUES
Dimensions :

81 x 35 x 32 mm (3.2 x 1.37 x 1.27 in.)

ENVIRONNEMENTALES
Immunit

é RF :

selon la norme EN-50130-4

Temp

érature de

fonctionnement :

de 0°C

à 55°C (32°F à 131°F)

Temp

érature de stockage :

de -20°C

à 60°C (-4°F à 140°F)

Humidit

é maximum :

95% sans condensation

Ces sp

écifications sont susceptibles d'être modifiées sans avis préalable.

Si vous avez des questions, veuillez contacter votre fournisseur.

INFORMATION DE COMMANDE

Modèle Description
WL T62

Détecteur de choc et d'ouverture sans fil, 433/868 MHz,
Blanc/Marron

Advertising