RISCO Group Wireless Shock and Contact Detector User Manual

Wl t6s, Wireless shock detector, Installation instructions

Advertising
background image

WL T6S

Wireless

Shock Detector

Installation

Instructions

United Kingdom
Tel: +44-161-655-5500

[email protected]

USA
Tel: +1-631-719-4400
[email protected]
Italy
Tel: +39-02-66590054
[email protected]

Spain
Tel: +34-91-490-2133
[email protected]
France
Tel: +33-164-73-28-50
[email protected]

Belgium
Tel: +32-2522-7622

[email protected]

Brazil
Tel: +55-3661-8767
[email protected]

China
Tel: +86-21-52-39-0066

[email protected]

Poland
Tel: +48-22-500-28-40
[email protected]

Israel
Tel: +972-3-963-7777

[email protected]

RISCO Group Limited Warranty

RISCO Group and its subsidiaries and affiliates ("Seller") warrants its products to be
free from defects in materials and workmanship under normal use for 24 months from
the date of production. Because Seller does not install or connect the product and
because the product may be used in conjunction with products not manufactured by the
Seller, Seller cannot guarantee the performance of the security system which uses this
product. Seller's obligation and liability under this warranty is expressly limited to
repairing and replacing, at Seller's option, within a reasonable time after the date of
delivery, any product not meeting the specifications. Seller makes no other warranty,
expressed or implied, and makes no warranty of merchantability or of fitness for any
particular purpose.
In no case shall seller be liable for any consequential or incidental damages for breach
of this or any other warranty, expressed or implied, or upon any other basis of liability
whatsoever.
Seller's obligation under this warranty shall not include any transportation charges or
costs of installation or any liability for direct, indirect, or consequential damages or
delay.
Seller does not represent that its product may not be compromised or circumvented;
that the product will prevent any personal injury or property loss by burglary, robbery,
fire or otherwise; or that the product will in all cases provide adequate warning or
protection.
Buyer understands that a properly installed and maintained alarm may only reduce the
risk of burglary, robbery or fire without warning, but is not insurance or a guaranty that
such event will not occur or that there will be no personal injury or property loss as a
result thereof.
Consequently seller shall have no liability for any personal injury, property damage or
loss based on a claim that the product fails to give warning. However, if seller is held
liable, whether directly or indirectly, for any loss or damage arising under this limited
warranty or otherwise, regardless of cause or origin, seller's maximum liability shall not
exceed the purchase price of the product, which shall be complete and exclusive
remedy against seller. No employee or representative of Seller is authorized to change
this warranty in any way or grant any other warranty.
NOTE: This product should be tested at least once a week.


FCC NOTE (for 433MHz versions only):

This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
a) Reorient or relocate the receiving antenna.
b) Increase the separation between the equipment and receiver.
c) Connect the equipment to an outlet on a circuit different from that to which the receiver

is connected.

d) Consult the dealer or an experienced radio/TV technician.
FCC Warning
The manufacturer is not responsible for any radio or TV interference caused by
unauthorized modifications to this equipment. Such modifications could void the user's
authority to operate the equipment.
FCC ID: JE4RWT71X433

RTTE Compliance Statement

Hereby, RISCO Group declares that this equipment is in compliance
with the essential requirements and other relevant provisions of Directive
1999/5/EC.
For the CE Declaration of Conformity please refer to our website:

www.riscogroup.com.



© RISCO Group 08/14 5IN1341 D

GENERAL DESCRIPTION

The WL T6S is a Shock detector intended for internal use
that provides reliable 24-hour perimeter protection.
The detector employs an advanced digital microprocessor
to analyze the vibration signal received from the piezo
electric sensor.
This detector operates in conjunction with RISCO's
programmable receivers and is powered by a standard 3-
volt lithium battery.

MAIN FEATURES

• Digital Microprocessor with Intelligent Digital Signal
Processing
• Tri-color LED enables accurate and reliable calibration,

with “over-sensitive” and “under-sensitive” indications

• Gross attack detections
• Encapsulated bi-morph piezo electric sensor
• Dual stage adjustment potentiometer
• Back & Cover tamper protection

• Operates up to 300m (1000 ft) range (LOS)

• Uses one of more than 16 million addresses codes

• Fully supervised

DIPSWITCHES

Dipswitch Description

1

Used to enable or disable LED

Dipswitch Position

LED

ON

(Default)

Enabled

OFF

Disabled

2

Used to determine the sensitivity of the Shock detector

Dipswitch Position

Sensitivity

ON

(Default)

High

OFF

Low

NOTE: For fine tuning use the sensitivity trimmer.

3

Used to determine the time between the transmitter
supervision messages.

Dipswitch Position

Supervision Time

ON

65 minutes

OFF

(Default)

15 minutes

4

Not used

5

Not used

6

Used to determine the detector RF power
Dipswitch Position

RF Power Transmission

ON

Low

OFF

(Default)

High

LED INDICATION

After each detection, the LED turns ON momentarily.
On Low Battery condition, the LED will blink during each transmission.

GREEN

Indicates an alarm condition

RED

• Under-Sensitive indication
• Tamper indication
• Write message

ORANGE

Over-Sensitive indication

FRONT COVER REMOVAL

Remove the front cover as described in Figure 2.

TRANSMITTER/RECEIVER COMMUNICATION SET UP

The transmitter must identify itself to the system’s receiver by writing its
coded messages into the receiver’s address memory. This is accomplished
by performing the following steps:
a. Set the receiver to the Write Mode (follow the receiver’s instructions).
b. Remove the battery from the insulation material and reinsert it into the

transmitter, paying attention to the polarity (see Fig. 3).

c. Send a Write message by pressing both tamper buttons for at least 3

seconds.

d. Set the receiver to the Normal mode.
e. Verify that the receiver has identified the detector by generating a tamper

signal (by momentarily closing and opening both tampers).

NOTE: If for any reason it is necessary to re-send a write message, press both
of the tamper buttons (back and cover) for at least 3 seconds.

INSTALLATION INSTRUCTIONS

Considerations for wireless communication

a. For best wireless communication, place the unit at the highest

possible position.

b. Temporarily attach the unit to this point using two sided adhesive

tape.

c. Generate an Alarm or Tamper signal and verify that the receiver

has received the signal. If the signal is not detected, reposition the
transmitter and try again.

Considerations for installation

1. Select the intended position for installation, ensuring the surface is

clean and clear of any irregularities. Refer to Table 1 for details
about detection ranges for the different surface types.

2. Set the detector’s sensitivity as follows, using the sensitivity

trimmer:

i. With the unit set for normal operation, use a suitable

instrument to bang or tap the protected area.

ii. If the sensitivity needs adjustment, use a screwdriver to

adjust the trimmer (turn the trimmer control clockwise to
increase sensitivity or counter-clockwise to reduce
sensitivity).

iii. Repeat steps i and ii until the desired sensitivity level is

achieved. If required, you can set Dipswitch 2 to OFF to
reduce sensitivity range.

3. Close the front cover.

Table 1: Typical Detection Range

Surface Concrete Brick Wall

Steel

Glass

Wood

Plywood

Radius 1.5m (5ft) 2.5m (8.2ft) 3m (10ft) 3.5m (11.5ft) 3.5m (11.5ft) 4m (13ft)

The above values are typical and are subject to practical testing,
which must be performed for each installation. In some environments,
these values may differ from the values listed above.

FINAL MOUNTING

Separate the back part of the transmitter (Fig. 4), and mount all the
parts in place (Fig. 5).

SPECIFICATIONS

ELECTRICAL
Battery Type:

CR123 3V Lithium Battery

Current Consumption:

10µA standby

Frequency:

433.92 / 868.65 MHz

Supervision Transmission:

Every 15/65 minutes

Modulation Type:

ASK

Battery Life:

5 years depends on usage

PHYSICAL
Size:

81x35x32mm (3.2x1.37x1.27in.)

ENVIRONMENTAL
RF immunity:

According to EN-50130-4

Operating temperature:

0°C to 55°C (32°F to 131°F)

Storage temperature:

-20°C to 60°C (-4°F to 140°F)

Maximum humidity:

95% non-condensing

Specifications are subject to change without prior notice.
Should any questions arise please contact your supplier.

DESCRIPTION GENERALE

Le détecteur de Choc WL T6S est destiné à une utilisation
intérieure qui offre une protection périmétrique fiable
24h/24. Grâce à son microprocesseur numérique de
pointe, le détecteur analyse tout signal de vibration qui lui
est envoyé par le capteur piézo-électrique.
Alimenté par une pile au lithium de 3V standard, il
fonctionne en combinaison avec les récepteurs
programmables de RISCO.

CARACTERISTIQUES PRINCIPALES

• Microprocesseur avec traitement intelligent du signal

numérique

• Diode électroluminescente tricolore (LED) pour un

calibrage précis et fiable, avec indications "d'excès" et
"d'insuffisance" de sensibilité

• Détection d'attaques brutales
• Capteur piézo-électrique bimorphe intégré
• Potentiomètre à double réglage
• Autoprotection à l'arrachement et à l'ouverture
• Portée allant jusqu'à 300 m. (1000 ft.) (Champ libre)
• Utilise un code d'adresse parmis plus de 16 millions
• Durée de vie étendue de la pile
• Entièrement supervisé

DIPSWITCHES

Dipswitch Description

1

Utilisé pour activer ou désactiver la LED

Position du DIP LED
ON

(par défaut))

Activé

OFF

Désactivé

2

Utilisé pour déterminer la sensibilité du détecteur de choc

Position du DIP Sensibilité
ON

(par défaut)

Elevée

OFF

Faible

NOTE : Pour un réglage fin, utiliser le potentiomètre de
sensibilité.

3

Utilisé pour déterminer le délai entre l’envoie des messages
de supervision du transmetteur.

Position du DIP Délai de Supervision
ON

65 minutes

OFF

(par défaut)

15 minutes

4

Inutilisé

5

Inutilisé

6

Sert à déterminer la puissance de transmission RF.
Position du DIP Transmission RF
ON

Faible

OFF

(par défaut)

Elevée

INDICATIONS LED

Après chaque détection, la diode LED s'allume momentanément.
Lorsque la pile est faible (batterie faible) – la diode LED clignote à chaque
transmission.

VERTE

Indique une condition d'alarme

ROUGE

• Indique une insuffisance de sensibilité
• Indication de sabotage
• Message d'écriture

ORANGE

Indique un excès de sensibilité

RETRAIT DU COUVERCLE FRONTAL

Enlever le couvercle comme décrit en figure 2.

PARAMETRAGE DE LA COMMUNICATION

TRANSMETTEUR/ RÉCEPTEUR

Le transmetteur doit s'identifier auprès du récepteur du système en
inscrivant ses messages codés dans le registre d'adresses du récepteur.
Cette opération s'accomplit en exécutant les étapes suivantes :
a. Réglez le récepteur en mode écriture (suivez pour cela les instructions

correspondantes).

b. Retirez la pile de sa protection isolante et réinsérez-la dans le

transmetteur en respectant la polarité indiquée (cf. fig. 3).

c. Envoyez un message d'écriture en appuyant sur les deux contacts

d'autoprotection pendant au moins 3 secondes.

d. Réglez le récepteur en mode normal.

e. Vérifiez que détecteur a bien été identifié par le récepteur : pour cela,

générez un signal d'autoprotection (en fermant et ouvrant
momentanément les deux AP).

REMARQUE : si pour une raison quelconque, il s'avère nécessaire de renvoyer
un message d’écriture, il suffit pour cela d'appuyer simultanément sur les deux
contacts d'autoprotection (arrière et couvercle) pendant au moins 3 secondes.

INSTRUCTIONS D'INSTALLATION

Considérations pour la communication sans fil

a. Pour une meilleure communication, placez l'appareil le plus haut

possible.

b. Fixez provisoirement l'appareil en ce point en utilisant de l'adhésif

double face.

c. Générer un signal d'alarme ou d'AP et vérifiez que le récepteur a

bien reçu le signal. Si le signal d'alarme n'a pas été détecté,
repositionnez le transmetteur et réessayez.

Considérations pour l’installation

1. Choisissez l'endroit souhaité pour l'installation, en vous assurant

que la surface est bien propre et nette de toutes aspérités. Se
reporter au tableau 1 pour consulter les portées de détection selon
les différents types de surfaces.

2. Ajuster la sensibilité du détecteur comme suit, en vous servant du

potentiomètre de sensibilité :
(i) L'appareil étant en mode de fonctionnement normal, feignez, à

l'aide d'un instrument adapté, une intrusion (en cognant ou
frappant) au sein de la zone protégée.

(ii) Si la sensibilité requiert un ajustement, ajustez le réglage à

l'aide d'un tournevis (dans le sens des aiguilles d'une montre
pour augmenter la sensibilité, et dans le sens inverse pour la
réduire).

(iii) Renouvelez les étapes (i) et (ii) jusqu'

à obtenir le niveau de

sensibilité souhaité. Si nécessaire, vous pouvez mettre le
Dipswitch 2 sur OFF pour réduire la sensibilité.

3. Fermez le couvercle frontal.

Tableau 1 : Portées typiques de détection

Surface

Béton

Mur de briques

Acier

Verre

Bois

Contreplaqué

Rayon

1,5 m

2,5 m

3m

3,5 m

3,5 m

4m

Les valeurs indiquées ci-dessus sont des valeurs typiques et doivent
être soumises à un test pratique à réaliser à chaque installation. Dans
certains environnements, ces valeurs peuvent être différentes de
celles du tableau ci-dessus.

ASSEMBLAGE FINAL

Séparez la partie arrière de l’émetteur (Fig. 4), et montez toutes les
pièces (Fig. 5).

SPECIFICATIONS

ELECTRIQUES

Type de batterie :

pile lithium 3V CR123

Consommation électrique :

10µA en veille

Fréquence :

433.92 / 868.65 MHz

Transmission de supervision :

toutes les 15 / 65 minutes

Type de modulation :

ASK

Durée de vie de la pile :

5 ans selon utilisation

PHYSIQUES
Dimensions :

81 x 35 x 32 mm

ENVIRONNEMENTALES

Immunité RF :

selon la norme EN-50130-4

Température de
fonctionnement :

de 0°C à 55°C

Température de stockage :

de -20°C à 60°C

Humidité maximum :

95% sans condensation

Ces spécifications sont susceptibles d'être modifiées sans avis préalable.
Si vous avez des questions, veuillez contacter votre fournisseur.

D

© RIS

C

O

BA
TT

E

R

Y

+

-

SW
1

PIE
ZO

SE
NS
OR

MIN MAX

AN
TE

NN
A

SW
2

x

DIPSWITCH

LE

D

ON

1 2 3 4 5 6

Fig. 1

Advertising