RISCO Group iWISE DT Grade 2 Detector User Manual

Iwise dt, English, Français español

Advertising
background image

GENERAL DESCRIPTION

• iWISE DT: Dual Technology Detector offering both MW and

IR technologies which include ACT™ and trouble indication.

LED DISPLAY

When LED Jumper is ON:
• YELLOW LED indicates PIR detection
• GREEN LED indicates MW detection
• RED LED indicates alarm
• At Power-up, the LEDs will blink continuously, one after the
other, until the end of the warm-up period.
• Flashing GREEN LED indicates trouble on MW channel.
• Flashing YELLOW LED indicates trouble on PIR channel.

INSTALLATION

PRELIMINARY CONSIDERATIONS

Before installation, study the space to be protected carefully i order to
choose the exact placement of the unit and lens for the best possible
coverage. Corner installations are recommended. The Detector should
be installed so that the beam patterns are at 45º (optimal) to
the intruder's expected path. Use Fig. 3 and step 5 for guidance.

WARNING: THE UNIT SHOULD NOT BE MOUNTED IN DIRECT
SUNLIGHT OR NEAR ANY HEAT SOURCES. THE DETECTION SECTORS
SHOULD BE POINTED EITHER TOWARDS A WALL OR TOWARDS THE
FLOOR (NOT TOWARDS WINDOWS NORCURTAINS). INSTALL ON
SMOOTH SURFACES ONLY.

OPENING THE FRONT COVER

To open the front cover, turn the screw 3 full turns counterclockwise.
With the screw loosened, press it 'in' to release the front cover.If a
fixing screw is not used, press the tab, which is located behind the
screw hole. The front cover can now be removed.

REMOVING THE PC BOARD

Loosen the holding screw, which is located on the right hand side of
the PCB and slide the PCB up until the screw enters the widened
opening. The PCB can now be lifted off.

MOUNTING

The iWISE DT can either be mounted on a flat surface or in a corner.
a. Open the knockout holes on the rear cover.
b. Insert the cable through the cable opening.
c. Mount the rear cover in its final location.
d. Seal the remaining holes with sealant.
e. After mounting the rear cover, return the PCB into its desired position.

PC BOARD ADJUSTMENT

After the Detector base has been mounted, reinstall the PCB. To choose
the correct vertical adjustment position for WIDE ANGLE LENS Use the
scale on the bottom left hand side of the PCB as follows:

MOUNTING HEIGHT AND SCALE POSITION
BASED ON ROOM SIZE:

Product Mounting Height LONG SHORT

RK810DT 2.1m-2.7m 10m 6m

(6'11"-8’10") (33') (19'8")

INSTALLATION

CONSIDERATIONS PREL IMINAIRES

Avant l'installation, étudiez avec soin l'espace à protéger afin de choisir
l'emplacement exact de l'appareil et de la lentille pour obtenir la meilleure
couverture possible du point de vue des dimensions. Il est recommandé de
procéder à des installations en coin. Le détecteur doit être installé de sorte que
les divers faisceaux se situent à 45 (optimal) du passage supposé de l'intrus.
Consultez la Fig.3 et l’étape n° 5 pour vous guider.
ATTENTION! L'APPAREIL NE DOIT PAS ÊTRE MONTÉ EN EXPOSITION
DIRECTE À LA LUMIÈRE DU SOLEIL NI À PROXIMITÉ DE SOURCES DE
CHALEUR. LES ZONES DE DÉTECTION DOIVENT ÊTRE DIRIGÉES SOIT VERS
UN MUR SOIT VERS LE SOL (ET NON VERS UNE FENÊTRE NI VERS DES RIDEAUX).
À INSTALLER SUR SURFACES LISSES SEULEMENT.

OUVERTURE DU COUVERCLE FRONTAL

Pour ouvrir le couvercle frontal, effectuez 3 tours complets de vis dans le sens inverse
des aiguilles d'une montre. Une fois la vis relâchée, appuyez-la pour dégager le
couvercle frontal. Si vous n'utilisez pas de vis de maintien, appuyez sur la languette
située derrière le trou de la vis. Vous pouvez à présent retirer le couvercle frontal.

RETRAIT DU TABLEAU PC

Dévissez la vis de maintien qui est située sur le côté droit du PCB (PC Board) et faites
glisser le PCB jusqu’à ce que la vis entre dans l'ouverture élargie. Le PCB peut
maintenant être soulevé et retiré.

MONTAGE

Le iWISE DT peut être monté soit une surface plane soit angulaire.
a. Ouvrez les trous situés sur le couvercle arrière.
b. Introduisez le câble dans l'ouverture qui lui est destinée.
c. Installez le couvercle arrière à sa place finale.
d. Bouchez les trous restants avec du mastic.
e. Après avoir monté le couvercle arrière, remettez le PCB dans la position souhaitée.

RÉGLAGE DU TABLEAU PC

Après avoir monté la base du détecteur, réinstallez le PCB. Pour choisir le réglage
vertical qui convient à la LENTILLE GRAND ANGLE installée à une hauteur située
entre 2.1m et 2.7m (6’11” - 8’10”), utilisez l'échelle de grandeur indiquée sur le
côté inférieur gauche du PCB comme suit:
POSITION DE L'ÉCHELLE BASÉE SUR LES
DIMENSIONS DE LA PIÈCE POUR RK115D ET

DESCRIPCION GENERAL
• iWISE DT: Detector DSP de Tecnología Dual ofreciendo ambas tecnologías MW e
IR que incluyen ACT™ e indicación de fallas.

CARACTERISTICAS DEL iWISE DT

• Tecnologías Dual IR y MW
• ACT™ - Tecnología Anti - Cloak
• Cobertura -10/15/25m (33/50/82 ft)
• montaje flexible de altura – hasta 2.7m (8’10”)
• Indicación de fallas
• Zona de Sabotaje
• Compensación de Temperatura Verdadera (Patentada)
• Ajuste del alcance por microondas
• Lentes Pigmentadas para filtración de luz blanca
• Bajo consumo de corriente
• Alta Inmunidad de RF 30V/m
•Procesamiento de señal de interferencia antifluorescente
• Amplio espacio de cableado
•Optimización del alcance por medio de PCB móvil
• Eslabón giratorio en la unión pared/rincón o en el techo

(con tamper de pared – opcional)

INDICADORE DEL LED
Cuando el cable de conexión del LED está en posición ON:
• LED AMARILLO indica detección PIR
• LED VERDE indica detección MW
• LED ROJO indica alarma
• En el periodo del ciclo inicial, los LEDs van a centellear continuamente, uno
después del otro, hasta el final de periodo de calentamiento.
• LED VERDE intermitente indica problemas en el canal MW.
• LED AMARILLO intermitente indica problemas en el canal PIR.

INSTALLATIÓN

CONSIDERACIONES PRELIMINARES

Antes de la instalación, estudie el espacio a ser cuidadosamente, para
poder elegir la mejor ubicación de la unidad y de las lentes para la mejor cobertura
posible. Son recomendadas instalaciones en los rincones. El Detector deberá
ser instalado de tal manera que la dispersión del rayo esté a 45° (óptimo) del
camino previsto del intruso. Use la Fig 3 y el Paso 5 para orientación.

ADVERTENCIA: LA UNIDAD NO DEBE SER MONTADA FRENTE A LUZ SOLAR
DIRECTA O CERCA DE FUENTES DE CALOR. LOS SECTORES DE DETECCION
DEBEN APUNTAR O EN DIRECCION A LA PARED O EN DIRECCION AL PISO.
(NO HACIA VENTANAS O CORTINAS). INSTALE SOLAMENTE SOBRE
SUPERFICIES LISAS.

ABRIENDO LA TAPA DELANTERA

Para abrir firmemente la tapa delantera, gire el tornillo 3 vueltas
completas en sentido opuesto a las agujas del reloj. Con el tornillo
aflojado aprételo para a dentro para liberar l a tapa delantera.
Si un tornillo de fijación no es usado, aprete la aleta, que está
ubicada detrás del agujero del tornillo. La tapa delantera puede
ahora ser removida.

REMOVIENDO LA PLACA DEL PC

Afloje el tornillo de mantenimiento, que está ubicado en el lado
derecho del PCB y deslice el PCB hacia arriba hasta que el tornillo
entre en la apertura ensanchada. El PCB puede ahora ser
desplegado.

MONTAJE

El iWISE puede ser montado en una superficie plana o en un rincón.
a.Abrir los agujeros pre-marcados en la tapa posterior.
b.Insertar los cables a través de la apertura para cables.
c.Montar la tapa posterior en su ubicación final.
d.Cerrar los agujeros que quedan con sellante.
e.Después de montar la tapa posterior, retornar el PCB a su posición
deseada.

AJUSTES DE LA PLACA DEL PC

Después que la base del detector haya sido montada, reinstale el PCB.
Para elegir la posición correcta del ajuste vertical para las LENTES
DE GRAN ANGULAR instaladas a una altura entre 2.1m - 2.7m
(6’11” - 8’10”) use la escala que se encuentra en el lado izquierdo
inferior del PCB, como sigue:
POSICION EN LA ESCALA BASADA EN EL TAMAÑO
DE LA PIEZA PARA

ENGLISH

DESCRIPTION GÉNÉRALE

iWISE DT: Détecteur à double technologie - technologies MW
et IR - comportant un mode ACT™ et indication de panne.

AFFICHAGE À DIODES LED
Lorsque le cavalier LED est allumé (ON):
• La diode LE D JAU N E indique une détection P I R,
• La diode LE D VE RTE indique une détection MW,
• La diode LED ROUGE indique une alarme
• Au moment de la mise sous tension, les diodes LED clignotent continuellement,
l'une après l'autre, jusqu'à la fin de la séquence d'échauffement.
• Si la diode LED VERTE s'allume, elle indique une panne du canal MW.
• Si la diode LED JAUNE s'allume, elle indique une panne du canal PIR.

FRANÇAIS

ESPAÑOL

DUAL TECHNOLOGY

iWISE

DT

RTTE Compliance Statement
Hereby, RISCO Group declares that this equipment is in compliance with the essential
requirements and other relevant provisions of Directive 1999/5/EC. For the CE Declaration
of Conformity please refer to our website: www.riscogroup.com.

© RISCO Group 02/09

5IN815DT E

UK Tel: +44-161-655-5500
E-mail: [email protected]

ITALY Tel: +39-02-66590054
E-mail: [email protected]

SPAIN Tel: +34-91-490-2133
E-mail: [email protected]

FRANCE Tel: +33-164-73-28-50
E-mail: [email protected]

BELGIUM Tel: +32-2522-7622
E-mail: [email protected]

U.S.A Tel: +305-592-3820
E-mail: [email protected]

BRAZIL Tel: +55-11-3661-8767
E-mail: [email protected]

CHINA Tel: +86-21-52-39-0066
E-mail: [email protected]

POLAND Tel: +48-22-500-28-40
E-mail: [email protected]

ISRAEL Tel: +972-3-963-7777
E-mail: [email protected]

RISCO Group Limited Warranty

RISCO Group and its subsidiaries and affiliates ("Seller") warrants its products to be free from defects in materials and

workmanship under normal use for 24 months from the date of production. Because Seller does not install or connect the

product and because the product may be used in conjunction with products not manufactured by the Seller, Seller cannot

guarantee the performance of the security system which uses this product. Seller's obligation and liability under this warranty

is expressly limited to repairing and replacing, at Seller's option, within a reasonable time after the date of delivery, any

product not meeting the specifications. Seller makes no other warranty, expressed or implied, and makes no warranty of

merchantability or of fitness for any particular purpose. In no case shall seller be liable for any consequential or incidental

damages for breach of this or any other warranty, expressed or implied, or upon any other basis of liability whatsoever.

Seller's obligation under this warranty shall not include any transportation charges or costs of installation or any liability for

direct, indirect, or consequential damages or delay. Seller does not represent that its product may not be compromised

or circumvented; that the product will prevent any personal injury or property loss by burglary, robbery, fire or otherwise;

or that the product will in all cases provide adequate warning or protection.

Buyer understands that a properly installed and maintained alarm may only reduce the risk of burglary, robbery or fire

without warning, but is not insurance or a guaranty that such event will not occur or that there will be no personal injury or

property loss as a result thereof. Consequently seller shall have no liability for any personal injury, property damage or loss

based on a claim that the product fails to give warning. However, if seller is held liable, whether directly or indirectly, for any

loss or damage arising under this limited warranty or otherwise, regardless of cause or origin, seller's maximum liability shall

not exceed the purchase price of the product, which shall be complete and exclusive remedy against seller.

No employee or representative of Seller is authorized to change this warranty in any way or grant any other warranty.

WARNING: This product should be tested at least once a week.

RK815DT

2.1m-2.7m 15m 6m

(6'11"-8’10") (

49'2"

) (19'8")

m

5

2

m

0

.

2

-

m

8

.

1

)

'

2

8

(

)

"

7

6

-

"

1

1

'

5

(

FOR IMQ
Operating temperature: 5ºC TO 40ºC (41ºF TO 104ºF)
FOR IMQ LEVEL 2
Use the RA91T000000A Swivel

SYNTONISATION DE LA ZONE PROTÉGÉE:
Faites glisser le tableau vers le haut - pour abaisser les faisceaux et réduire la portée.
Faites glisser le tableau vers le bas - pour élever les faisceaux et augmenter la portée.
Ensuite, serrez la vis pour fixer le PCB dans la position voulue.

CÂBLAGE DES TERMINEAUX (Cf. Fig. 6)

Connectez le câble au bloc du terminal en haut du PCB comme suit:
12 VDC: Entrée de l'alimentation électrique.
ALARME: Sortie normalement fermée.
AUTOPROTECTION: Sortie sèche normalement fermée.

INSTALLATION DES CAVALIERS

Le iWISE dispose de deux cavaliers qui peuvent être en positon de marche
(IN - en utilisation) ou en position fermée (OUT - hors utilisation). Les
cavaliers inutilisés doivent être placés sur une broche dans le seul but d'éviter
de les perdre. Cf. Fig. 2

TEST DE PASSAGE À PIED

Deux minutes après avoir réalisé la mise sous tension (séquence d'échauffement),
faites un test de passage à pied pour vérifier l'efficacité du détecteur sur la
totalité de la zone protégée. Le RK825DT nécessite une période d'échauffement
plus longue allant jusqu’ à QUATRE minutes, ce qui permet une capacité de
captage puissante sur longue portée avec sensibilité accrue.

REMARQUE:
• Assurez-vous de remettre en place le couvercle frontal avant d'effectuer le
test de passage.
• La portée MW peut se régler à l'aide du potentiomètre situé au bas du PCB. Il
est très important de régler le potentiomètre sur le niveau le plus bas possible
permettant de couvrir la totalité de la surface de la zone àprotéger. N'utilisez
pas le le mode ACT™ en application longue portée /couloir si vous prévoyez le
passage d'objets derrière ou à côté de la zone àprotéger (le couloir). Cf. Fig.5

SPÉCIFICATIONS
ELECTRIQUES
Consommation (sous 12 VDC)
Hors alarme: 19mA
En alarme: 38mA à 12 VDC (44mA à 12 VDC pour RK825DT)
Voltage exigé: 9-16 VDC
Contacts d'alarme: 24 VDC, 0.1A.
Temps minimal de changement d’état: 2.2 seconds
Contacts d'autoprotection : 24 VDC, 0.1A
Résistance de la boucle de Détection: Etat ouvert: plus que 108 ohm
Etat fermé: moins que 1 ohm
Ondulations résiduelles
maximales admissibles: 0.25V créte à créte
OPTIQUES
Filtrage: Protection lumière blanche

PHYSIQUES
Dimensions: 127.6 x 64.2 x 40.9mm
(5 x 2.5 x 1.6 in.)

ENVIRONNEMENTALES

Immunité RF Répond à la norme EN50130-4
Température de fonctionnement: -20°C to 55°C (-4°F à 131°F)
Température de stockage: -20°C to 60°C (-4°F à 140°F)
Indice de protection: IP 31/IK 02
Taille du càble à utiliser: Fil de diamètre au moins 0.5 mm pour une longueur ne
dépassant pas 300 mètres.

ORGANISME DE CERTIFICATION:

POUR IMQ:
Température de fonctionnement : 5° C à 40° C (41° F à 104° F)

POUR IMQ NIVEAU 2:
Utilisez le pivot RA91T000000A

AJUSTE DEL AREA PROTEGIDA:
Deslice la placa hacia arriba – para bajar los rayos y reducir el alcance.
Deslice la placa hacia abajo – para levantar los rayos y aumentar
el alcance. Cuando haya completado, aprete el tornillo para
asegurar el PCB en la posición deseada.

CONEXIÓN CABLEADO DE LOS TERMINALES (Var Fig. 6)

Conecte el cable al bloque de la terminal en la parte superior del
PCB como sigue:
12 VDC: Entrada de la fuente de alimentación
ALARMA: Salida normalmente cerrada.
TAMPER: Salida seca normalmente cerrada.

JUMPER POSICIONES

El iWISE tiene dos cables de conexión que pueden estar en in
(usado) o out (sin uso). Los cables de conexión sin uso deben
ser colocados en una clavilla solamente, para evitar su pérdida.
Var Fig. 2

PRUEBA DE MOVIMENTO

Dos minutos después de activar (periodo de calentamiento), haga
la prueba de movimento con el Detector por toda el área protegida

para verificar si la unidad está funcionando propiamente. El RK-

825DT necesita un periodo de calentamiento más largo, de
CUATRO minutos, lo que permite una capacidad más poderosa
de sensibilidad a largo alcance, con sensibilidad aumentada.

NOTA:
• Asegúrese de haber recolocado la tapa delantera antes de

ejecutar la Prueba de Caminata.

• El alcance del MW puede ser ajustado usando el potenciómetro,
que está ubicado al fondo del PCB. Es importante poner el
potenciómetro en la regulación más baja posible que todavía
proveerá suficiente cobertura a toda el área protegida. No instale
el Detector en la aplicación de largo alcance/corredor, si Usted
espera que pueden haber objetos móviles detrás o al lado de la
requerida área protegida. (el corredor). Refiérase a la Fig. 5

DISPOSICION FINAL

Después de completar la instalación y las etapas de pruebas,
asegúrese que todos los cables de conexión estén en las posiciones
deseadas. La unidad está ahora preparada para ser usada.

ESPECIFICACIONES

ELECTRICA
Consumo de corriente: 19mA a 12 VDC
38mA a 16 VDC
(MAX con todos LED's ON)
Requisitos de Voltaje: 9-16 VDC
Contactos del Alarma: 24 VDC, 0.1A
Contactos del Tamper: 24 VDC, 0.1A

OPTICA
Filtración: Protección contra Luz Blanca

AMBIENTAL

Inmunidad RF According a EN50130-4
Temperatura de operación:

-20°C hasta 55°C (-4°F hasta 131°F)

Temperatura de Almacenamiento:

-20°C hasta 60°C (-4°F hasta 140°F)

PARA IMQ
Temperatura de Operación: 5ºC hasta 40ºC (41ºF hasta 104ºF)

PARA IMQ NIVEL 2:
Use eslabón giratorio RA91T000000A eslabón giratorio

AFNOR CERTIFICATION: 11 rue Francis de Pressensé
93571 LA PLAINE SAINT-DENIS Cedex
http://www.marque-nf.com
CNPP: BP 2265, 27950 ST MARCEL,
http://www.cnpp.com

FISICA

Tamaño: 127.6 x 64.2 x 40.9mm

(5 x 2.5 x 1.6 in.)

RK825DT

Producto Altura da Montaje LONG SHORT

RK810DT 2.1m-2.7m 10m 6m

(6'11"-8’10") (33') (19'8")

RK815DT

2.1m-2.7m 15m 6m

(6'11"-8’10") (

49'2"

) (19'8")

m

5

2

m

0

.

2

-

m

8

.

1

)

'

2

8

(

)

"

7

6

-

"

1

1

'

5

(

RK825DT

Produit Hauteur de montage LONG

COURT

m

5

2

m

0

.

2

-

m

8

.

1

)

'

2

8

(

)

"

7

6

-

"

1

1

'

5

(

RK825DT

Note: For corridor lens, set position to “LONG”
and use the mounting height of 2.5m for all types of detectors

Note:Para la lente de pasillo, colocarlo en la posición “LONG”
y utilizar una altura de montaje de 2,5 m. para todos los tipos
de detector.

Note : Pour les lentilles rideau, positionner le détecteur sur “LONG” et utiliser
une hauteur de montage de 2,5m pour tous les types de détecteurs.

• The MW range can be adjusted by using the potentiometer,which is
located at the bottom of the PCB. It is important to set the potentiometer
to the lowest possible setting that will still provide enough coverage for
the entire protected area, and then to make a walk test near/under the
detector and (if required), to re-adjust the potentiometer. (see Fig 5)
Do not use ACT™ mode in long range /corridor applications if you are
expecting that there will be moving objects behind or on the side of the
required protected area (the corridor) Refer to Fig 5.

FCC NOTE:

This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions:
1. This device may not cause harmful interference and
2. This device must accept any interference received, including
interference that may cause undesired operation.
FCC ID: JE4CSMDT
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications.

SPECIFICATIONS
ELECTRICAL
Current consumption: 19mA at 12 VDC
38mA at 16 VDC
(MAX with all LED's ON)
Voltage requirements: 9-16 VDC*
Alarm contacts: 24 VDC, 0.1A
Tamper contacts: 24 VDC, 0.1A

OPTICAL
Filtering: White Light Protection
PHYSICAL
Size: 127.6 x 64.2 x 40.9mm
(5 x 2.5 x 1.6 in.)

ENVIRONMENTAL
RF immunity According to EN50130-4
Operating temperature: -20ºC to 55ºC (-4ºF to 131ºF)
Storage Temperature: -20ºC to 60ºC (-4ºF to 140ºF)
* Power to be supplied by 5A max. power source using safety
approved wires, with a min. Gauge of 20AWG.

ETL UL639 Compliance:
Connect the detector to a power source capable of supplying at
least 4h of Standby power. For bank vaults installation, connect to
a power source capable of supplying at least 72h of standby power

FINE TUNING OF THE PROTECTED AREA:
Slide the board upwards - to lower the beams and reduce the range.
Slide the board downwards - to raise the beams and increase the range.
When completed, fasten the screw to secure the PCB in the desired position.

TERMINAL WIRING (See Fig. 6)

Connect the cable to the terminal block at the top of the PCB as follows:
12 VDC: Power supply input.
ALARM: Normally closed output.
TAMPER: Normally closed dry output.

JUMPER SETTING

The iWISE has two jumpers that can either be in (used) or out (unused).
Unused jumpers should be placed on one pin only to prevent their loss.
See Fig 2.

WALK TEST

NOTE:
Two minutes after applying power (warm-up period), walk test the
Detector over the entire protected area to verify proper operation
of the unit. The RK825DT needs a longer warm-up period of FOUR
minutes, which enables a powerful long range sensing capability
with increased sensitivity.

However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
a) Reorient or relocate the receiving antenna.
b) Increase the separation between the equipment and receiver.
c) Connect the equipment to an outlet on a circuit different from that
to which the receiver is connected.
d) Consult the dealer or an experienced radio/TV technician.
FCC WARNING:
The manufacturer is not responsible for any radio or TV interference caused by
unauthorized modifications to this equipment. Such modifications could void the
user's authority to operate the equipment.

RK810DT 2.1m-2.7m 10m 6m

(6'11"-8’10") (33') (19'8")

RK815DT

2.1m-2.7m 15m 6m

(6'11"-8’10") (

49'2"

) (19'8")

Advertising