RISCO Group LightSYS 2 Supplement V3.0x User Manual

Page 4

Advertising
background image

Item

Grade 2

Enhanced

Features

Explanation

USER CODES

4 digits

6 digits

NOTE: changing the number of code digits will
require re-defining all current user codes.

ANTI CODE RESET 4 digits

6 digits

EVENT LOG

250 events 500 events

LightSYS2 always supports 512 events

INSTALLER
TAMPER

Not
required

For enhanced mode, the system control bit “ENGR.
TAMPER” shall be defined as YES.

Menu = [Programming][System][Controls][Advanced]

YES: A Tamper event causes a Lockout condition

which can only be reset by the Installer code or
by Anti-Code.

NO: A Tamper event does not cause a Lockout

condition

TROUBLE RESET

Not
required

For enhanced mode, the system control bit “Rest
Trouble” shall be defined as YES.

Menu = [Programming][System][Controls][EN50131]

YES: A System Trouble condition must be

acknowledged by the user

NO: A System Trouble condition will reset

automatically when clear

DETECTOR MASK
AND TROUBLE

Not
required

For enhanced mode, triple end-of-line termination is
supported to identify detector masking and trouble
(trouble for all Grades).

INHIBIT KEYPAD

Not
required

For enhanced mode, 10 invalid code entry attempts
will lock the keypad for 90 seconds (relevant for all
user codes and operations – arming, disarming, etc.)

DUAL PATH
ARMING
PREVENTION

Required

If there is a communication fault with the
monitoring station (by PSTN, TCP/IP, GSM, or STU)
the panel will not be ready to arm.

© RISCO Group, 12/2014. All rights reserved.

5IN2164 C

TRIPLE EOL ZONE INPUT