ON TICK

Tasking Statement

SYNTAX:

ON TIC K n,t GOS UB line/label
ON TIC K n,t G O S U B

PURPOSE:

To cause periodic program branching.

REMARK S:

This statement is used when periodic tasks must be executed. The GO SUB is executed every t
seconds. n is the tick num ber and ranges fr om 0 to 2. Up to 3 O N TIC K subrou tines can exec ute
simultaneously.

There are three TICK timers in CAMBASIC. The parameter n ranges from 0-2. The TICK timers
are independent of each other.

The range of t is 0.005 to 327.68 seconds. The GOSU B branch occurs every t seconds unless the
second syntax is executed. Not specifying a line number or label after GOSUB disables the ON tick
subroutine.

Every t seconds an interval flag is set. At the conclusion of the current CA MBASIC command, a
GOSU B branch occur s.

See Multitasking Chapter for mor e information.

RELATED:

C L E A R T IC K , T I C K

EXAMPLE:

10 ON TICK 1, 1 GOSUB 50
20 PRINT "*"
30 FOR X=0 TO 600:NEXT
40 GOTO 20
50 PRINT TICK(1)
60 RETURN

ERROR:

< Data negative> – for t and n
< Data out of range> - if n > 2
< Time> 327.67 sec> - for t
< Can’t compile> – if line/label does not exist