Digital gauge – Retrotec Air Leakage Test Systems Selector User Manual

Page 3

Advertising
background image

Digital Gauge

DM-2 Digital Gauge Dimensions

Weight

14oz/397g

Size

8.75 x 4.25 x 3 in

22.2 x 10.8 x 7.6 cm

Power

AC adapter

4 NiMH AA rechargeable batteries

Accuracy + 1 %

[Mode] Units Available

Pressure: Pascals, inches, water column, psf

PrB 53.5 Pa

Flow: cfm, L/s, m³/s, m³/h

Flow 253.5 cfm

Flow per area: CFM/ft², L/s/m², CFM/100ft², m³/h/m², cfm/1000ft²

0.25

Leakage Area: EqLA (Canadian) and/or EfLA (US): cm², in², ft²

EqLA 12.8

EqLA and EfLA per area: in²/100ft², cm²/m², in²/in²

1.15

Air changes per hour according to volume entered: /h

2.7

Hole Flow: CFM, L/s, m³/s, m³/h

103.7 cfm

Flow/

Area

/h

Air

Chg

in²/100ft²

@10.0Pa

Hole

Flow

ft²

@10.0Pa

EqLA/

Area

cfm/ft²

@75.0Pa

Page 3 of 8

The Retrotec DM-2 displays every possible result with manual and fully automatic (or computerized) fan speed control.

Connect to FanTestic PC software via

USB for data acquisition, automatic

control, or data monitoring.

Match tube to same color port.

Use an unlimited

length of ethernet

style Speed Control

Cable to control fan.

Recharge

batteries.

[Set Pressure]

Control to any pressure.
[Volume Area]

For Air Changes and ELA per area.

[Set Speed]

Set to any % speed.

[@ Pressure]

Immediate results estimated

at any test pressure.

[Jog/

Hold

]

Adjust up/down in 5 Pa increments

for multi-point tests.

[Setup]

Add/remove modes and devices.

Advertising