5 To Trigger the Oscilloscope

RIGOL

DS6000 User’s Guide

5-5

Trigger Coupling


Trigger coupling decides which kind of components will be transmitted to the trigger
circuit. Note to distinguish it with Channel Coupling.
 DC: allow the DC and AC components to pass the trigger path.
 AC: block all the DC components and attenuate signals lower than 8 Hz.
 LF reject: block the DC components and reject the low frequency components

lower than 5 kHz.

 HF reject: reject the high frequency components higher than 50 kHz.

Press MENUSettingCoupling in the trigger control area (TRIGGER) at the
front panel to select the desired coupling type (the default is DC).
Note: trigger coupling is only valid in edge trigger.