MSO2000A/DS2000A User’s Guide
11-3
Note
[1]
: Memory depth=Sample rate×Horizontal time base×Number of grids horizontally on
the screen; wherein, for MSO2000A/DS2000A, “Number of grids horizontally on the screen” is
14. Therefore, the maximum end frame of waveform record is also related to the “Sample
rate” and “Horizontal time base”.
Table 11-1 Memory Depth and Total Frames
Memory Depth
Maximum End Frame
Auto
65000
14 k points
8128
140 k points
508
1.4M points
63
14M points
7
56M points
2