Float

Float Hanger

Chemical Feed Hose

Proportioning Valve

3.0 Automatic Chemical Feed Continued

3.1 Metering Tip Replacement:

To adjust the amount of cleaning

concentrate being drawn, simply

remove the plastic supply tube

from the chemical feed metering

valve (Figure 1). Unscrew the

colored metering tip and replace

with the tip that corresponds to

the portable dilution ratio for

your cleaning product (Figure

2). Reconnect the plastic supply

tube.
3.2 Liquid Concentrates:

The machine comes with the orange metering tip installed at the factory. This tip is

rated for a 0.4 oz. of chemical per gallon of water, which is a standard dilution ratio

for the most popular liquid cleaning

products on the market. Refer to your

product’s dilution ratio and select the

proper metering tip from the chart

displayed in Figure 2.
3.3 Fresh Water Rinse:

For

fresh water rinsing, simply leave the

chemical supply tube in the solution

tank.
3.4 Manual Filling:

To use the

machine without the automatic filling

system, simply pre-mix your solution.
3.5 Setup:

Inside the solution tank

is a bottle float. Check the chemical

feed supply foot valve for debris and

clean if necessary. Insert the line into

the cleaning concentrate so that it

touches the bottom of the bottle. Set

cleaning concentrate on the machine

or inside the fresh water solution tank

opening. Connect the fill hose to the

quick disconnect located on the back

of the machine.

Figure 2: Metering Tip Dilution Ratios

Tip Color

Concentrated Dilution

Ratio

(oz./gal.)

Liquids

Powders

Tan

0.30

---

Orange

0.40

---

Turquoise

0.50

---

Pink

0.75

---

Clear

1.00

---

Brown

1.12

---

Red

1.50

---

White

1.75

---

Green

2.00

0.25

Blue

2.50

0.30

Yellow

3.75

0.47

Black

5.00

0.63

Purple

8.50

1.06

Gray

11.50

---

None

16.25

---

3.0 Automatic Chemical Feed Continued

3.5 Setup Continued:

Attach the water supply hose to any available faucet. It

may require adapters to fit the various faucet combinations you will encounter. Never

force a threaded fitting. Place a towel over the faucet connection so that any spray

will be controlled. Turn on the water and check the hose connections for leaks.
The solution tank will fill approximately half full (about 5-gallons). As the tank is

filling, cleaning concentrate is being drawn into the solution tank.
3.6 Shutdown:

Before the end of each job, turn off the water supply to prevent

the solution tank from becoming completely full. With the cleaning completed and

the solution pump turned off, disconnect the fill hose from the faucet, drain the water

in the fill hose back into the solution tank and remove the fill hose. Remove the

chemical feed supply tube from the chemical solution jug, clean the filter and place

into the solution tank. Vacuum out the solution tank and clean the solution tank water

filter.

4.0 Water and Chemical Dilution – Auto Fill

The chemical dilution rate is controlled by the metering tip and the dilution rate can

only be changed by changing the metering tip (see section 4.2).
4.1 Chemical Feed Setup
• Remove the chemical feed hose from the solution tank. Make sure the float is

attached to the valve and hanging freely.

• Place the end of the hose into a container of liquid chemical.
• If the tip is removed and the proportioning system operated with no tip, the

dilution rate will be 8:1 (the equivalent to adding 16-1/4 oz. of chemical to each

gallon of water).

• If a fresh water rinse with no chemical is desired, simply leave the chemical feed

hose inside the solution tank.