0 wiring diagram, Returned material authorization (rma) procedure, 0 safety instructions – Sandia 2-Gallon Spot Extractor User Manual

Page 5: 0 set-up / prepare unit for use

Advertising
background image

(8) 2-Gallon Spot Extractor

5.0 Wiring Diagram

CAUTION – Electrical wire colors may vary. Determine start and end point of

each wire to confirm connection point.

2-Gallon Spot Extractor (5)

Returned Material Authorization (RMA) Procedure

The original purchaser must contact the manufacturer to follow correct RMA/warranty

procedures. A copy of the RMA Sheet but be included and enclosed in the box with

returned item. No returns shall be authorized unless the proper RMA procedures are

followed. It is the responsibility of the distributor to repair the customer’s equipment as

soon as possible. If the distributor does not have the facilities to repair the equipment, it

may be shipped or taken to an authorized service center for repair.
The customer must contact the manufacturer prior to working on or changing out any

parts, etc. The manufacturer must issue an RMA Sheet containing approved labor time

and replacement parts. Do not send parts or equipment back to manufacturer without

an RMA Number and approval. No labor will be paid for, nor part costs paid for or

reimbursed that have not been previously approved by manufacture. All warranty work

must be approved and authorized to qualify and appropriate warranty procedures must be

followed.

1.0 Safety Instructions

WARNING: PLEASE READ AND SAVE! FOLLOW THESE PRECAUTIONS

WHEN USING YOUR SPOT EXTRACTOR.
• DO NOT operate this unit if any part of the unit appears to be damaged.
• DO NOT operate if ground plug is broken.
• DO NOT operate if the unit is in standing water.
• DO NOT use volatile substances or operate where volatile substances exist.
• DO NOT service while unit is running or connected to electricity. Unplug the unit!
• DO NOT use water more than 120 degrees Fahrenheit.
• DO NOT use solvents with this unit.
• DO NOT use as a dry vacuum.
• DO NOT use unit unless completely assembled.
• Use only liquid detergents. Powders do not fully dissolve and damage motor.
• Always us defoamer. Foam will suspend moisture particles that damage motor.

2.0 Set-Up / Prepare Unit for Use

DO NOT EXPOSE TO RAIN. STORE INDOORS.
• All spot extractors – no matter what the time of year – are shipped with antifreeze

in the pump and solution lines. Prior to first use, fill the tank with one quart of warm

water. Attach the hose and using the hand tool, flush out the system by spraying the

one quart of water through the pump.

• Attach the 1-1/2 inch vacuum hose and the brass quick disconnect.
• Fill the base unit (the recovery tank must be removed) with warm water (less than

100 degrees Fahrenheit). Fill to approximately 4 inches from the top. Use a liquid

detergent made for carpet cleaning or upholstery. Read and mix to the dilution ratios

as directed.

Advertising