Terminating the scsi bus, Installing the tape drive – Exabyte 8505XL User Manual

Page 18

Advertising
background image

8

Chapter 1: Installation

Figure 1-3

Setting the Drive Sled for Single-Ended Operation

Note:

Your system disk should always be set to SCSI ID 1. Be sure each SCSI

device on a bus has a unique SCSI address (ID). The SCSI bus cannot
function properly if more than one device has the same SCSI ID.

Terminating the SCSI Bus

The internal SCSI channels in a rackmount or deskside system and a data
storage unit are configured so that front-loading devices (FLDs) can be
added or removed without affecting the channel termination. No additional
termination is required.

Installing the Tape Drive

The drive must be properly mounted on a drive sled and configured for a
channel and single-ended operating protocol, as described in “Configuring
the Drive Sled for Single-Ended Operation” on page 7.

Channel A =
single−ended

A

A

B

Single−ended, 50−pin SCSI drive on channel A

No jumpers set;
reserved for future use.

H2

H1

B

Channel B =
differential

A

Advertising
This manual is related to the following products: