CAUTION!

NEVER open the

boiler filling cap before ALL

the remaining steam has been

released from the steam

generator and the steam

generator has cooled. To

release the steam, press the

On/Off button to the “Off”

position and push the steam

button on the iron until no

more steam comes out of the

iron. Then open the boiler filler

cap slowly.

Read all instructions before using the EURO-PRO Operating LLC Steam Generator
Iron and follow all the instructions and safeguards carefully.

ADDITIONAL IMPORTANT SAFEGUARDS

DO NOT OVER TIGHTEN THE
BOILER FILLER CAP

To close the boiler filler cap, turn

clockwise until the point where you feel

friction – do NOT close too tightly. The

boiler filler cap has a gasket which can

be flattened and damaged if the cap is

closed too tightly. If the gasket is

damaged, steam may escape while the

steam generator is being used. If the

boiler filler cap is damaged and steam

is leaking, call EURO-PRO Operating

LLC customer service to purchase a

replacement boiler filler cap.

NEVER LEAVE THE HOT IRON
RESTING ON THE IRON REST
FOR LONG PERIODS OF TIME

The lifespan of your steam generator

will be reduced if the iron is left idle at

high temperatures for extended

periods of time. If the iron is not in use,

reduce the temperature to the lowest

temperature setting on the temperature

control thermostat, turn the steam

generator “Off” and remove the power

cord from the electrical power outlet.

WARRANTED FOR REGULAR
HOUSEHOLD USE

While the Steam Generator Iron is a

professional type ironing system; it is

intended for and warranted only for

normal household use. The iron and/or

steam generator should not be used

for more than fifteen (15) hours per

week in approximately three (3) hour

intervals.

TROUBLSHOOTING

Do not operate the steam generator with a damaged cord, plug or if the iron or any

other part of the system has been dropped or damaged. To avoid the risk of electric

shock, do not disassemble or attempt to repair the ironing system. Return the

appliance to EURO-PRO Operating LLC (see Warranty) for examination and repair.

Incorrect re-assembly or repair can cause a risk of electric shock or injury to persons

when the ironing system is used.

POSSIBLE CAUSES

SOLUTIONS

1. Order new boiler filler cap

from customer Service at

1 (800) 798-7398.

1. Gasket is broken because

boiler filler cap was closed too

tightly or cap was opened

while tank was full of steam

and gasket broke.

Steam Leaking

From The Boiler

Filler Cap

1. Clean steam generator as

per instructions.

2. Use demineralized/ distilled

water after cleaning the

tank.

1. Residue is water tank.
2. Not using demineralized/

distilled water.

Dirty Or Yellow

Steam Is

Coming Out Of

The Iron

1. Turn the temperature

control dial to the marks

between 2 and 3 dots.

2. Wait for generator to be

fully heated.

1. Soleplate temperature is too

low to iron with steam.

2. Generator is not fully heated.

Drops Of Water

Leak From The

Iron Soleplate

1. Turn the temperature

control dial to the desired

setting.

1. Temperature is set at

“Minimum”.

The Soleplate

Remains Cold

1. Press the On/Off button to

the “ON” position.

2. Fill with water as per

instructions.

3. Make sure that the On/Off

button is in the “OFF”

position and plug the unit

into an electrical outlet.

4/5. The heating time for the

generator is approximately

11-13 minutes. Watch for

the steam ready light to go

off indicating that steam is

ready.

1. On/Off button is not in the

“ON” position.

2. Steam generator has no more

water.

3. Unit is not plugged in.
4. Steam is not visible because

the temperature of the

soleplate is at maximum and

room temperature is high.

5. Generator is not fully heated.

No Steam Is

Released

Through The

Iron

PROBLEM

A WORD ON WATER

For best results we recommend using
100% demineralized/distilled water.
You can use regular tap water in your
steam generator, but should the water in
your area be hard water we strongly
recommend the use of 100%
demineralized/distilled water. This will
prolong the life of your generator and
reduce the frequency of required generator
cleaning, as well as the possibility of
staining due to accumulated impurities.
DO NOT USE WATER PROCESSED
THROUGH A HOME WATER
SOFTENING SYSTEM OR BOTTLED
MINERAL WATER.

DO NOT OVERFILL THE STEAM
GENERATOR

When empty, the steam generator can be

filled with 26 U.S. fl. oz. of demineralized/

distilled water. Do NOT overfill. Overfilling

the water tank can cause water drops to

come out of the steam holes. See filling

instructions on page 5.