During automatic operation, the control performs a 90 second water
dump cycle every 8 or 12 hours of pump operation. This interval can
be toggled between 8 or 12 hours by simultaneously holding the ‘Cool’
and ‘Fan’ buttons for 5 seconds. The selected interval is displayed for
a short time. This action also starts a manual dump cycle.

Ventilation Operation (Fan Mode)

The fan speed is set by the user, the water pump is turned off.

This mode is activated by pressing the ‘Fan’ button. A green LED
is illuminated, and the LCD indicates fan speed. Pressing the ‘Fan’
button again deselects this mode.

Pressing the ‘Up’ button selects maximum Fan speed, and ‘Hi’ is
displayed in the LCD; pressing the ‘Down’ button selects minimum
Fan speed, and ‘Lo’ is displayed in the LCD.

Time Delay Operation (Timer Mode)

Delayed start or fi nish in ‘Cool’ or ‘Fan’ mode.

The ‘Timer’ button is used to set a delay period of 2, 4 or 8 hours,
depending on how many times the button is pressed.

If the cooler is operating in ‘Cool’ or ‘Fan’ modes when the ‘Timer’
button is pressed, the delay period determines when the cooler will
switch off. If the cooler is Off when the ‘Timer’ button is pressed,
the delay period determines when the cooler switches on.

The starting mode is indicated by a fl ashing LED. You can change
this mode by pressing the appropriate button (‘Cool’ or ‘Fan’).

You can cancel the Timer function at any time by pressing the ‘Timer’
button until all the timer LED’s go out.

In The Event Of A Power Outage

If the cooler is operating in ‘Cool’ or ‘Fan’ mode when power is
interrupted, the cooler will resume in the same mode of operation
when the power is restored.

If the cooler was in any ‘Timer’ mode at the time of a power
interruption, the cooler will remain off when power is restored.

Wiring Diagrams

Thermostat Operation

Automatic Operation (Cool Mode)

The fan and water pump are controlled automatically to achieve the
desired comfort level.

This mode is activated by pressing the ‘Cool’ button. A blue LED
is illuminated, and for a few seconds the LCD will display the
‘Set’ temperature. Pressing the ‘Cool’ button again deactivates this
mode.

The Set temperature (the target temperature for control) may be altered
by repeatedly pressing or holding the ‘Up’ and ‘Down’ buttons. The
LCD will display ‘Set’ rather than ‘Room’ temperature for a short
time after pressing the ‘Up’ or ‘Down’ button.

On starting, if the pads in the cooler are too dry, the fan may be delayed
from starting until the pads have absorbed some water. This is called
Pre-wet and lasts for 2 minutes, indicated by a fl ashing blue LED.
Selecting ‘Fan’ and then ‘Cool’ will bypass the pre-wet and cause the
fan and pump to start immediately. (If cooling is required).

Start cooler. Install both inspection panels, start pump, and allow

to operate until pads are wet.

Check amperage. With pads wet and unit started, check amperage

draw with an amperage meter.

Adjust pulley if necessary. If amperage draw is less than mo-

tor rating, turn off electrical power and
remove inspection panels. Unplug mo-
tor inside cooler, this will protect you
from someone turning on unit while
you are working inside. This should be
done for your safety. Adjust pulley to a
larger diameter and readjust belt tension,
plug motor in, install inspection panels,
and retest amperage draw. Repeat this
process until correct amperage draw is attained. Increasing motor
pulley diameter increases amperage draw. Decreasing motor pulley
diameter decreases amperage draw (see Fig. 6).

CAUTION:

Do not operate cooler with larger amperage draw

than specifi ed on motor plate.

120 Volt

240 Volt

Decrease
Amperage

Fig. 6

FAN MOTOR

THERMOSTAT

RECEPTACLE

RECEPTACLE

CIRCULATING PUMP

RECEPTACLE

DRAIN PUMP

120 VAC

WHITE

RED

COOLER TERMINAL BOX

WHITE

GREEN

BLACK

GREEN

WHITE

BLUE

=WIRE NUT

SWITCH LEADS

VIOLET

BLUE

YELLOW

GRAY

BLACK

RED

GREEN

WHITE

GRAY

GROUND

TOGGLE SWITCH

(11)

FL
o

FH
i

FCo

m

LIN

K

L1

N

NL
in

k

PP

PCo

m

DP

DCo

m

DUMP

PUMP

FAN

PWR. SUPPLY

ORANGE

ORANGE

BROWN

BROWN

ORANGE

BLUE

WHITE

GREEN

SWITCH LEADS

=WIRE NUT

WHITE

GREEN

BLACK

GREEN

WHITE

COOLER TERMINAL BOX

RED

BLUE

GREEN

WHITE

BLUE

ORANGE

BROWN

BROWN

ORANGE

ORANGE

WHITE

240 VAC

DRAIN PUMP

RECEPTACLE

CIRCULATING PUMP

RECEPTACLE

RECEPTACLE

THERMOSTAT

FAN MOTOR

PWR. SUPPLY

FAN

PUMP DUMP

DCom

DP

PC

o

m

PP

NLink

N

L1

LI

N

K

FC
o

m

FH
i

FLo

(11)

TOGGLE SWITCH

GROUND

GRAY

WHITE

GREEN

RED

BLACK

GRAY

YELLOW

BLUE

VIOLET

Advertising
This manual is related to the following products: