The cables of the optional sensors can not be extended.

The sensor must be mounted horizontally.

2.4 Wiring the Data Cable with the Solar-Log™

The Sensor Box Professional Plus is connected via the RS485 gateway with the Solar-Log™. The 4-core con-

nection cable between the irradiance sensor and the Solar-Log™ is used for data exchange and 12 V power

supply. A separate mains adapter is not necessary.

The connection cable can be extended (max 50 m). Please be sure that the supply voltage 10,5 VDC rea-

ches the end of the connection cable. For longer distance please use a cable with bigger wire cross section.

For outdoor use, the connection must be protected in conformity with IP54. For indoor wiring, please use a

shielded data cable. The shield of the cable must be connected with a potential equalisation. The 4 wires of

the connection cable have to be connected with the Solar-Log™ connection plug.

Warning!

Interchanging the connection cables may result in damage to sensor.

Connection plug Solar-Log™

Sensor Box Professional Plus

1 (Data+)

Data+ A (brown)

2 (+12 V)

+12 V (red)

3 (GND)

GND (black)

4 (Data-)

Data- B (orange)