2

CDX3 SERIES

MODEL NO.

CDX3-75

CDX3-100

CDX3-125

HEATING INPUT RATE IN BTU/HR
(High fire / Low fire)

75,000 / 56,250

100,000 / 75,000

125,000 / 93,750

HEATING CAPACITY IN BTU/HR
(High fire / Low fire)

69,750 / 52,312

93,000 / 69,750

116,250 / 87,187

HEIGHT OF CASING

46-1/4”

46-1/4”

46-1/4”

WIDTH OF CASING

17”

21”

24”

DEPTH OF CASING

27-1/2”

27-1/2”

27-1/2”

WARM AIR OUTLET

15 x 18

19 x 18

22 x 18

RETURN AIR INLET

15 x 22

19 x 22

22 x 22

DIA. OF FLUE

2”

3”

3”

DIA. OF COMBUSTION
AIR INTAKE

2”

3”

3”

FLOWRATE from .2” & .5” w.c.
EXTERNAL STATIC PRESSURE

COOLING

COOLING

COOLING

@COOLING TAP A (CFM)

1000

1200

1400

@COOLING TAP B (CFM)

800

1000

1200

@COOLING TAP C (CFM)

1200

1400

1600

@COOLING TAP D (CFM)

1400

1600

2000

HEATING

HEATING

HEATING

@HEATING TAP C
(CFM @ High fire / Low fire)

1012 / 826

1340 / 1094

1673 / 1366

TEMPERATURE RISE (°F)

65 / 60

65 / 60

65 / 60

BLOWER MOTOR HP

.5

.75

1

POWER CHOKES

-

2.65Mh

2.1Mh

LARGEST RECOMMENDED
AIR CONDITIONER

3.5 Ton

4 Ton

5 Ton

SIZE OF FILTERS

21-3/4” x 14”(2)

21-3/4” x 14”(2)

21-3/4” x 14”(2)

NOTES:
1. Heating capacity based on annual fuel utilization efficiency rated by manufacturer.
2. On all outlet and inlet dimensions, the first dimension is width.
3. Electrical characteristics at 115 volts, 60 Hz., 1 phase (less than 15 amps. for all models).
4. All specifications are subject to change without notice.