maIntenance

The ENVI-RO requires very little maintenance. Regular cartridge

replacement is the only normal requirement, and a very important

one. In typical service, the cartridge change-out schedules are as

listed below.
every 6 months
- replace the Sr cartridge:

Open both by-pass valves.

Remove power from system by unplugging power cord.

Close the inlet valve.

Follow instructions on the SR cartridge label. Place a bucket

under the cartridge to catch any excess water that may spill from

the head. Remove the old cartridge by turning the cartridge to

the left until it stops and pulling it downward until it is free from

its head.
Remove the outer shrink-wrap and protective cap from the new

SR cartridge.
Align the lugs on the new cartridge with the slots in the head.

Holding the head and cartridge firmly, press the cartridge

upward into the head fully, and then turn the cartridge to the

right until it stops.
Disconnect 3/8” OD line from SR Cartridge to Booster Pump

inlet at Booster Pump. Route line into bucket and secure. Plug-in

power cord.
Route a blue line from the 3/8” storage tank drain valve to drain

temporarily. Open inlet valve. Open storage tank drain valve.

Drain storage tank until system starts processing water. Close

storage tank drain valve.
Once a solid flow of water has been established, flush 1 gallon.

Unplug power cord. Re-connect 3/8” OD line to Booster Pump

inlet. Plug in power cord.
Close both by-pass valves.

every 12 months
– Sanitize the storage tank and lines:

Refer to “Disinfection” section - steps 1-8, for sanitization

procedure.

– replace the ro cartridge:

Open both by-pass valves.

Remove power from system by unplugging power cord.

Close the inlet valve.

Follow instructions on the MR cartridge label. Place a bucket

under the cartridge to catch any excess water that may spill from

the head. Remove the old cartridge by turning the cartridge to

the left until it stops and pulling it downward until it is free from

its head.
Remove the outer shrink-wrap and protective cap from the new

MR cartridge.
Align the lugs on the new cartridge with the slots in the head.

Holding the head and cartridge firmly, press the cartridge

upward into the head fully, and then turn the cartridge to the

right until it stops.
Remove both capillary restrictors temporarily.

Route a blue line from the 3/8” storage tank drain valve to drain

temporarily. Open inlet valve. Open storage tank drain valve.

Plug-in power cord.

Drain storage tank until system starts processing water. Once

a solid flow of water has been established, flush 5 gallons from

tank drain (about 10 minutes). Unplug power cord.

WARNING

do not uSe tHIS Product Water! It may contain

a preservative solution from the ro cartridge and

should not be consumed!

Re-install capillary tubes.

Close both by-pass valves.

– replace the Post carbon cartridge:

Open both by-pass valves.

Remove power from system by unplugging power cord.

Close the inlet and both outlet valves.

Route a blue line from the 3/8” storage tank drain valve to drain

temporarily. Open storage tank drain valve. Drain storage tank.

Close storage tank drain valve.
Follow instructions on the Post Carbon cartridge label. Place a

bucket under the cartridge to catch any excess water that may

spill when removing lines. Remove lines, note flow direction, then

remove cartridge.
Install new cartridge, in same flow direction as original cartridge.

Connect lines.
Plug-in power cord. Once a solid flow of water has been

established, flush 5 gallons from tank drain.
Close storage tank drain valve.

Open the inlet and both outlet valves.

Close both by-pass valves.