50 WATT SINGLE OUTPUT

SWITCHING POWER SUPPLIES

I — INTRODUCTION

SCOPE OF MANUAL. This instruction manual covers the installation and operation of the Kepco RAX 50W Series of Switching
Power Supplies. For service information, please refer to the Service Manual for the RAX 50W Series, which can be purchased
either from your Kepco Representative, or by writing directly to: Kepco Inc. 131-38 Sanford Avenue, Flushing, New York 11352,
U.S.A. When ordering a Service Manual, please state Model Designation and Serial Number of your RAX power supply.
This information can be found on the nameplate of the unit.

DESCRIPTION. The Kepco RAX 50W Series consists of seven models of switching power supplies, with a single output as
shown in Table 1. Units may be operated with either 115V a-c or 230V a-c 47-440Hz input. They will also operate on 240V to
370V d-c input. The RAX 50W Series employs a light weight ferrite core with 140 KHz switching frequency. Regulation is pro-
vided by pulse width modulation. A FET power stage, operating in the forward conversion mode provides a smooth isolated d-c
output. A triac “soft-start” circuit prevents excessive turn-on current surge. Overvoltage protection and optically isolated remote
TTL on-off control is provided. Current limiting with automatic recovery from short circuit is featured. Units are enclosed in a
wrap-around aluminum case with an LED “output present” light visible on the terminal side of the case.

Table 1 contains specifications and operating limits of individual RAX 50W Series models. Section II (following) contains specifi-
cations and operating limits common to all RAX 50W Series Models.

II — SPECIFICATIONS

The following specifications are at nominal input voltages at 25°C unless otherwise specified.

INPUT VOLTAGE: (Jumper selectable, see Section III, FIG. 3):

120V a-c nominal, range: 85 -132V a-c
220-240V a-c nominal, range: 170 -264V a-c
320V d-c nominal, range: 240 -370V d-c
For d-c input the jumper is placed in the 230V position.

INPUT SOURCE FREQUENCY:

Nominal 50/60 Hz; Range 47-440 Hz. (At 400 Hz the leakage current exceeds the VDE safety specification limit.)

TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RAX 50W SERIES

MODEL

RAX 3.3-10K

RAX 5-10K

RAX 12-4.2K

RAX 15-3.4K

RAX 24-2.1K

RAX28-1.8K

RAX 48-1K

OUTPUT VOLTS, d-c

3.3V

5V

12V

15V

24V

28V

48V

ADJUSTMENT RANGE

1.8 - 3.6V

4.0 - 5.5V

8.4 - 13.2V

12.0 - 16.5V

16.8 - 26.4V

19.6 -30.8V

32.6 - 52.8V

MAXIMUM

OUTPUT

RATINGS

(AMPS,

WATTS)

50° C amb.

10.0A/33W

10.0A/50W

4.2A/50.4W

3.4A/51W

2.1A/50.4W

1.8A/50.4W

1.0A/48W

60° C amb.

7.0A/23.1W

7.0A/35W

2.9A/35.3W

2.4A/35.7W

1.5A/35.3W

1.3A/35.3W

0.7A/33.6W

71° C amb.

4.0A/13.2W

4.0A/20W

1.7A/20.1W

1.4A/20.4W

0.8A/20.1W

0.72A/20.2W

0.4A/19.2W

CURRENT LIMIT (AMPS)

(1)

10.5 -11.0

10.5 -11.0

4.5 - 4.8

3.6 - 3.9

2.3 - 2.5

2.0 - 2.2

1.1 - 1.3

OVP RANGE (VOLTS)

3.9 - 4.8

6.0 - 6.9

13.7 - 15.7

17.0 - 19.5

27.0 - 30.5

32.0 - 35.0

55.0 - 63.0

RIPPLE

AND

NOISE

(2)

(mV p-p)

source (typ)

5

5

15

15

25

30

35

source (max)

10

10

30

30

40

60

90

switching (typ)

25

25

25

25

25

25

25

switching (max)

40

40

50

50

60

60

60

spike noise

(max)

(3)

100

100

170

200

290

330

530

(1)

Change of current setting with the specified variations for operating temperatures and source input voltage is within ±10% of the rated values.

(2)

Source component 2x source frequency, and switching component approximately 140KHz.

(3)

Measured with a 50 MHz bandwidth.

CAUTION: UNIT IS SET
TO 115V AC OPERATION