KEPCO RAX 100W User Manual

Page 2

Advertising
background image

2

228-1226 REV 3

072302

KEPCO, INC. " 131-38 SANFORD AVENUE " FLUSHING, NY. 11352 U.S.A. " TEL (718) 461-7000 " FAX (718) 767-1102

http://www.kepcopower.com " email: [email protected]

BROWNOUT VOLTAGE:

115V a-c input selection, 80V a-c min. (82V a-c min. for model RAX 28-3.5K)

230V a-c input selection, 160V a-c min. (164V a-c min. for model RAX 28-3.5K)

320V d-c input selection, 220V d-c min. (Jumper in 230V a-c position)

INPUT CURRENT: (maximum load at 50°C with nominal output voltage):

INPUT PROTECTION AND SOFT START: A triac soft start circuit reduces start-up surge. Units are protected against

shorts by an input fuse. Fuse value 5A.

INPUT SURGE: At 25°C from cold start:

NOTE: There are two input surges at turn-on:

EFFICIENCY: 75% typical (78% typical for model RAX 3.3-20K)

STABILIZATION:

TRANSIENT RECOVERY: A step load change from 50% to 100% of rated load in 50 microseconds or more, produces no

more than 4% output voltage excursion. Recovery to 1% of the original voltage is less than 1 millisecond.

OUTPUT HOLDING TIME: Output is maintained for 20 milliseconds minimum upon input interruption (30 milliseconds typi-

cal) with nominal input voltage and output load at 50°C current rating.

OVERVOLTAGE PROTECTION: Fixed, factory set. See Table 1. The overvoltage circuit is reset by interrupting input for

approximately 15 seconds.

OPERATING TEMPERATURE: 0 -71°C. See the derating graph, Figure 1.

STORAGE TEMPERATURE: -20°C to + 75°C.

HUMIDITY: 20% to 95% relative humidity, noncondensing

ISOLATION: (at 25°C ambient, 65% relative humidity):

Between input and output terminals, 3.75 KV a-c for 1 minute (with Y-capacitors removed).

Between input and output or chassis, 2000V a-c for 1 minute.

Between output terminals and chassis, 500V a-c for 1 minute.

INSULATION RESISTANCE: Between output and chassis, 100 megohms minimum (500V d-c)

LEAKAGE CURRENT:

0.5mA max at 120V a-c (U.L. Method)

0.75mA max at 240V d-c (U.L./VDE Method)

VIBRATION: Three Axes:

5-10 Hz., 10 mm amplitude

10-55 Hz., 2g

SHOCK: Three axes, 20g, 11 ms ±5msec pulse duration

INPUT SOURCE

NOMINAL INPUT VOLT-

AGE

MINIMUM INPUT VOLTAGE

120 V a-c input selection

1.8A typ. - 2.5A max.

2.3A typ. - 2.9A max.

220-240V a-c input selec-
tion

0.9A typ. - 1.3A max.

1.2A typ. - 1.6A max.

d-c input selection

0.7A max. (320V input)

1.0A max. (240V input)

INPUT SOURCE

FIRST SURGE (5ms max.)

SECOND SURGE (3ms max.)

120 V a-c input selection

17A max.

12A typ.

220-240V a-c input selec-
tion

34A max.

10A typ.

320V d-c input selection

34A max.

10A typ.

CHARACTERISTIC

TYPICAL

MAXIMUM

Source Effect (min - max)

0.8%

1.5%

Load Effect, measured at sensing terminals (10% - 100% load change)

0.8%

1.5%

Temperature effect (0 to 71°C)

1.0%

2.0%

Combined effect (envelope)

2.0%

4.0%

Drift (8 hr. at 25°C)

0.1%

0.5%

Advertising