Offline/reset switch -11, Figure 4‐3, Recommended shutdown procedure using – Enterasys Networks Enterasys Platinum Distributed Forwarding Engine 7G4285-49 User Manual

Page 69: Offline/reset switch, Figure 4-3 offline/reset switch

Advertising
background image

Overview of DFE Module Shutdown Procedure

DFE-Platinum Series Hardware Installation Guide 4-11

Figure 4-3 OFFLINE/RESET Switch

Recommended Shutdown Procedure Using OFFLINE/RESET
Switch

Before pulling a DFE module out of a chassis, 

press or tap on its OFFLINE/RESET switch for less than 1 second. 

Its CPU LED changes from solid green to blinking between green and amber, indicating 
that the DFE module is shutting down. At the end of the DFE module shutdown routine, 
the CPU LED changes to a 67%/33% sequence of amber/off, respectively, indicating the 
module is in a halt state. In this time it is safe to restart or remove the DFE module from 
the chassis.

When a controlled shutdown is initiated from the OFFLINE/RESET switch, you have 60 
seconds from the time the CPU starts flashing amber/off until the time the device is 
automatically restarted.

1 OFFLINE/RESET switch (in similar location on all DFE modules)

À

CPU

POE

1X

G

R

O

U

P
1

OFFLINE/

RESET

COM

MGMT

GROUP

SELECT

GROUP

1

2

3

4

5

6

1

2

3

4

7G4285-49

Gb ENET

Caution: Do not pull any DFE module out of an operating chassis before it has completed
its shutdown routine.

Precaución: No retire los módulos DFE del chasis en funcionamiento hasta que no se
haya terminado con la rutina de apagado.

Note: The only safe time to pull a DFE module out of the chassis is when the CPU LED is
blinking amber. Otherwise, system operation will be interrupted.