Fuse Replacement (12 Volt DC Charging/Power Adapter)

1. Remove plug from accessory outlet. Remove the gold cap by turning counter-

clockwise and lifting off.

2. Remove center pin and spring. Remove fuse.
3. Replace fuse with same type and size fuse (8 amp).
4. Replace center pin and spring inside plug.
5. Replace gold cap by turning clockwise.

Battery Replacement/Disposal

It is recommended that the unit be returned to Customer Service for
battery replacement.
This unit contains a maintenance-free, non-spillable, sealed lead-acid
battery. This battery is fully recyclable and should be accepted at any
location that accepts common automotive batteries. Examples of places
that accept these batteries are: county or municipal recycling drop-off centers, scrap
metal dealers and retailers who sell automotive replacement lead acid batteries.

WARNINGS

Do not dispose of the battery in fire, as this may result in an explosion.
Before disposing of the battery, protect exposed terminals with heavy-duty electrical tape to

prevent shorting (shorting can result in injury or fire).
Do not expose battery to fire or intense heat, as it may explode.

SPECIFICATIONS

12 Volt DC Specifications

Battery:

12 volt DC rechargeable, maintenance-free

Internal Battery Type:

Sealed, AGM lead-acid

Internal Battery Capacity:

12 volt, 19Ah/20 hour rate

Area Light :

Light Emitting Diode (LED)

Accessory Outlet Protection:

Self-resetting overload protection

DC Charging Adapter:

12 volt DC

AC Power Specifications

Output Power:

400 watts

Output Voltage:

120 VAC RMS

Output Frequency:

60 Hz ±4 Hz

Output Waveform:

Modified sine wave

Overheat Protection:

Yes

Overload Protection:

Yes

Output Short Circuit

Protection:

Yes

VEC1029FPOB_ManualEN_101606 10/16/06 5:17 PM Page 12