7

Installation

Installation Location

The appliance should be set up in a well ventilated, dry room on a firm and
level surface.

Warning! The appliance may not be exposed to spray or water splashes.
There is a danger of electrical shock!

Energy use is affected by the ambient temperature.
The appliance should therefore

not be exposed to direct sunlight;

not be installed next to radiators, cookers or other sources of heat;

only be installed at a location whose ambient temperature corresponds
to the climate classification, for which the appliance is designed.

The climate classification is stipulated on the serial plate which can be
found on the inner side of the lid. The following table shows which ambient
temperature is correct for each climate classification:

Climate classification

for an ambient temperature of

SN

+10 to +32 °C

N

+16 to +32 °C

ST

+18 to +38 °C

T

+18 to +43 °C

Model

ARCTIS 189 GT

ARCTIS 261 GT

Volume (gross)

litres

Volume (net)

litres

Height without/with roller

cm

Width

cm

Depth

cm

Weight

kg

Energy consumpt./24h

kWh

Freezing capacity

kg/24h

Hold-over time

hours

Rated power

W

189

184

87,6/88,3

93,5

66,5

49

0,53

23

43

75

261

255

87,6/88,3

119

66,5

57

0,64

27

47

100

Technical Specifications